6-90 RSC-M card replacement procedures
NTMX87
in an RSC-M
(continued)
Replacing an NTMX87 in an RSC-M
At the MAP display
1
2
At the MAP terminal
3
297-8223-550 Standard 04.02 November 2000
Proceed only under the following conditions:
•
a step in a maintenance procedure directed you to this card replacement
procedure
•
you are using the procedure to verify or to accept cards
•
your maintenance support group directed you to this procedure
WARNING
Loss of service
When you replace an NTMX87 circuit card in the RSC-M all
links served by that card must be BSYed. All active calls on
the affected links are lost. Make sure to perform this
procedure only during periods of low traffic.
Obtain an NTMX87 replacement circuit card. The replacement circuit card
must have the same product equipment code (PEC), including suffix, as the
circuit card you must remove.
To post the RSC-M/RCO2 with the defective card(s), type
>MAPCI;MTC;PM;POST RCO2 rco2_no
and press the Enter key.
where
rco2_no
is the number of the RCO2 with the defective card(s)
Example of a MAP response: