Nortel DMS 100 Series Maintenance Manual page 309

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

Diagnostic history is not supported
for this PM type.
If peripherals are not present on the requested PM, the following message
appears:
None.
The following is an example of the DISP command that uses the DIAGHIST
option with a selected PM. The system displays the diagnostic history for all
XPMs of the PM requested.
>MAPCI;MTC;PM;DISP DIAGHIST RCO2
Diagnostic History for RTPK04AY
Report generated 95/03/29 WED at 13:36:20
RCO2 0
Long–Term Failure (LTF) last reset: 95/03/24 08:44:53
UNIT 0
12:28:23
Last diagnostic failure: 95/03/24 12:28:23
Note: Cards reported by the mate unit are indicated by a "*"
UNIT 1
16:12:15
Last diagnostic failure: 95/03/28 15:41:45
Using the DIAGHIST option with the QUERYPM command
An option called DIAGHIST is added to the QUERYPM command. This
option displays the history of diagnostic failures for the posted peripheral.
Each unit displays the short- and long-term failure counts. The last reset date
and time for short term failure counters appears for each unit. The last reset
date and time for long-term failure counters appears for the entire node. Reset
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
Short–Term Failure (STF) last reset: 95/03/29
DIAGLIST
CPM AUDIT
FAC AUD
EXTDIAG
CARDLIST
NTMX73
Short–Term Failure (STF) last reset: 95/03/28
DIAGLIST
EXTDIAG
FAC AUD
CPM AUDIT
CARDLIST
NTMX79
NTMX76
NTMX77
RSC-M trouble isolation and correction 8-21
STF
LTF
1
4
0
3
0
3
STF
LTF
1
10
STF
LTF
0
4
0
1
0
1
STF
LTF
0
6
1
1
0
1