6-48 RSC-M card replacement procedures
NTMX74
in an RSC-M
(continued)
15
16
17
18
19
20
297-8223-550 Standard 04.02 November 2000
and press the Enter key.
where
unit_no
is the number of the inactive RCO2 unit zero or one
If the PMRESET command
passes
fails
To reload the inactive RCO2 unit, type:
>LOADPM UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the inactive RCO2 unit zero or one
If the LOADPM command
passes
fails
To return the inactive RCO2 unit to service, type:
>RTS UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the RCO2 unit busied in step 7
If RTS
passes
fails
Send defective cards for repair according to local procedure.
Record the date the card is replaced. Record the serial number of the card,
and the problems that prompt replacement of the card. Go to step 21.
Return to the procedure that directed you to this procedure. At the point
where a defective card list was produced, identify the next defective card on
the list. Go to the correct card replacement procedure for that card in this
manual.
For additional help to replace this card, contact the next level of maintenance.
Do
step 16
step 15
Do
step 16
step 20
Do
step 17
step 20