6-62 RSC-M card replacement procedures
NTMX76
in an RSC-M
(continued)
11
At the shelf
12
13
At the MAP terminal
14
297-8223-550 Standard 04.02 November 2000
RCO2
0 ISTb
Unit0:
Inact ManB
Unit1:
Act
ISTb
Bsy INACTIVE
RCO2 0 Unit 0
If the BSY command
passes
fails
To reset the inactive RCO2 unit, type:
>PMRESET
UNIT
and press the Enter key.
where
unit_no
is the inactive RCO2 unit number zero or one.
WARNING
Static electricity damage
Wear a wrist strap that connects to the wrist-strap grounding
point of the modular supervisory panel (MSP) to handle
circuit cards. The wrist strap protects the cards against static
electricity damage
Locate the circuit card you want to replace.
Note: The NTMX76 circuit cards are in slot 8 of unit zero, and slot 20 of
unit one.
To replace the card use the common replacing a card procedure in this
document. When the procedure is complete, return to this point.
Note: If the circuit card you replace has switches, make sure the switches
on the replacement circuit card have the same settings.
To reset the inactive unit, type:
>PMRESET UNIT unit_no
and press the Enter key.
where
Links_OOS: CSide
Bsy Passed
Do
step 11
step 20
unit_no
NORUN
0 , PSide
1