6-68 RSC-M card replacement procedures
NTMX77
in an RSC-M
(continued)
8
At the cabinet
9
10
11
297-8223-550 Standard 04.02 November 2000
Example of a MAP response:
Unit0:
Inact SysB
Unit1:
Act
ISTb
RCO2 0
SwAct Passed
If the MAP response
is SWACT passed
is other than listed here
A maintenance flag (Mtce) can appear. This flag indicates that maintenance
tasks that the system initiates are in progress. Wait until the flag disappears
from the status lines for both RCO2 units before you proceed to the next step.
Place a sign on the active unit with the words Active unit-Do not touch. Do
not attach this sign with magnets or tape.
To manually busy (ManB) the inactive unit, type
>BSY INACTIVE
and press the Enter key.
Example of a MAP response:
RCO2
0 ISTb
Unit0:
Inact ManB
Unit1:
Act
ISTb
bsy INACTIVE
RCO2 0 Unit 0
If the BSY command
passed
failed
To reset the inactive RCO2 unit, type
>PMRESET UNIT unit_no NORUN
and press the Enter key.
where
unit_no
is the rco2 unit number (0 or 1)
Mtce
Do
step 8
step 23
Links_OOS: CSide
Bsy Passed
Do
step 11
step 23
0 , PSide
1