Nortel DMS 100 Series Maintenance Manual page 212

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

6-60 RSC-M card replacement procedures
NTMX76
in an RSC-M
(continued)
4
5
6
297-8223-550 Standard 04.02 November 2000
RCO2
SysB
0 Quit
PM
0
2 Post_
RCO2
3 ListSet
4
RCO2
0 ISTb
5 TRNSL
Unit0:
6 TST
Unit1:
7 BSY
8 RTS
9 OffL
10 LoadPM_
11 Disp_
12 Next_
To determine the location of the RCO2, that contains the circuit card to
replace, type:
>QUERYPM
and press the Enter key.
Example of a MAP response:
PM Type: RCO2 PM No.: 0 PM Int. No.: 9 Node_No: 24
PMs Equipped: 53 Loadname: UK00ADU6 EEPRom Load:
BNK0N205
WARM SWACT is supported and available
RCO2 0 is included in the REX schedule.
REX on RCO2 0 has not been performed.
Node Status: {OK, FALSE}
Unit 0 Act,
Unit 1 Inact, Status: {OK, FALSE}
Site Flr RPos Bay_id Shf Description Slot EqPEC
RSC-M 00
C02
RSC-M 00
C02
Determine the state of the RCO2 unit that associates with the circuit card to
replace:
If the state of the RCO2 unit is
active
inactive
To perform a Switch of Activity (SWACT) of the units, type:
>SWACT
and press the Enter key.
Example of a MAP response:
ManB
OffL
0
2
0
0
0
Links_OOS:
CSide
Inact ISTb
Act InSv
Status: {OK, FALSE}
RSC-M 00
05
RSC-M 00
47
Do
step 6
step 8
CBsy
ISTb
0
2
0
1
1, PSide
1
RCO2: 000
MX85AA
EXT:LEFT
01:13 MX86AA
InSv
25
1