Nortel DMS 100 Series Maintenance Manual page 122

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

5-12 RSC-M alarm clearing procedures
PM RSC-M/RCO2
critical
(continued)
Clearing a PM RSC-M/RCO2 critical alarm
At the MAP display
1
2
3
297-8223-550 Standard 04.02 November 2000
Enter this procedure from the PM system-level alarm clearing procedure step
that identified an RCO2-associated fault.
To silence the alarm, type:
>MAPCI;MTC;SIL
and press the Enter key.
To identify the RCO2 that has faults, type
>Pm;disp STATE cbsy RCO2
and press the Enter key.
Example of a MAP response:
CBsy
RCO2: 2
or
None
If None appears on the MAP screen, display the SysB RCO2. To display the
SysB RCO2, type
>disp STATE SYSB RCO2
and press the Enter key.
Example of a MAP response:
SysB
RCO2: 2
To post the CBsy or SysB RCO2, type
>POST RCO2 rco2_no
and press the Enter key.
where
rco2_no
is the number of the RCO2 displayed in step 2
Example of a MAP response:
RCO2
SysB
PM
3
RCO2
0
ATTENTION
ManB
Offl
CBsy
0
1
0
2
ISTb
InSv
1
4
12
1
2
9