Nortel DMS 100 Series Maintenance Manual page 244

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

6-92 RSC-M card replacement procedures
NTMX87
in an RSC-M
(continued)
6
RCO2 P-side link connections (Sheet 1 of 2)
Card Location
RCO2 main, shelf,
pos. 05
Left ext. half shelf
297-8223-550 Standard 04.02 November 2000
If C-side links are
not defective
To display the peripheral-side (P-side) links associated with the NTMX87
circuit card, type
>TRNSL P
and press the Enter key.
Example of a MAP response
Link
0:
REM1 11 0
Link
1: Carrier of Class – Trunk ;Status:OK
Link
2: Carrier of Class – Trunk ;Status:SBsy
Link
3: Carrier of Class – Trunk ;Status:SBsy
Link
4: Carrier of Class – Trunk ;Status:SBsy
Link
5: Carrier of Class – Trunk ;Status:OK
Link
6: Carrier of Class – Trunk ;Status:OK
Link
7: Carrier of Class – Trunk ;Status:OK
Link
8:
REM1 11 1 0;Cap MS;Status:OK;
The following table shows the P-side link configuration for an RSC-M cabinet.
The cabinet has three RCO2 main shelves and two extension half shelves.
Note 1: A RCO2 cabinet can include other configurations like two RCO2
main shelves and four extension half shelves. Consult office
administration or review office records for P-side link configurations other
than the configurations mentioned in the following table.
Note 2: If the RCO2 has an associated extension half shelf, consult office
administration or review office records for the P-side link configuration.
Note 3: NTMX82 packlets number from 0 to 3 starting at the top of each
NTMX87 circuit card.
Links for
MX87
MX82
Slot No.
Card 0
12
0, 1
16
8, 9
14
16, 17
4
24, 25
6
32, 33
Do
step 6
0;Cap MS;Status:OK
Links for
Links for
MX82
MX82
Card 1
Card 2
2, 3
4, 5
10, 11
12, 13
18, 19
20, 21
26, 27
28, 29
34, 35
36, 37
;MsgCond:OPN
MsgCond:OPN
Links for
MX82
Card 3
6, 7
14, 15
22, 23
30, 31
38, 39