Nortel DMS 100 Series Maintenance Manual page 239

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

Note 1: Perform this step for each link ManB.
Note 2: To test the other links that associate with the RCO2, execute the
procedures in this step. Execute the procedures for each link until all links
are tested.
If the test of the link(s)
passes
fails
19
To return to service (RTS) the links, type
>RTS LINK link_no
and press the Enter key.
where
Note: To RTS the other links that associate with the RCO2, execute the
procedures in this step. Execute the procedures for each link until all links
are RTS.
If RTS
passes on all links
fails
20
Proceed to the common returning a card procedure in this document.
21
The procedure is complete. Return to the maintenance procedure that
directed you to this card replacement procedure. Continue as directed.
22
For additional help, contact the next level of maintenance.
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
link_no
is the number of the link ManB in step 11
link_no
is the number of the link tested in step 18
RSC-M card replacement procedures
in an RSC-M
Do
step 19
step 22
Do
step 20
step 22
6-87
NTMX82
(end)