Nortel DMS 100 Series Maintenance Manual page 176

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

6-24 RSC-M card replacement procedures
NT6X92
in an RSC-M
(continued)
At the shelf
11
12
13
14
297-8223-550 Standard 04.02 November 2000
RCO2
0 ISTb
Unit0:
Inact ManB
Unit1:
Act
Bsy INACTIVE
RCO2 0 Unit 0
If the BSY command
passes
fails
WARNING
Static electricity damage
Wear a wrist strap that connects to the wrist-strap grounding
point of the modular supervisory panel (MSP) to handle
circuit cards. The wrist strap protects the cards against static
electricity damage.
Locate the circuit card to replace.
Note: The NT6X92 circuit cards, are in slots 6 and 7 of unit 0, and slots
21 and 22 of unit 1.
To replace the card, use the common replacing a card procedure in this
document. Complete the procedure and return to this point.
Note: If the card you replace has switches, make sure the switches on the
replacement circuit card have the same settings.
The next action depends on the reason you performed this procedure.
If a maintenance procedure
directs you to this procedure
does not direct you to this proce-
dure
Remove the sign from the active unit. Return to the maintenance procedure
that sent you to this procedure. Continue as directed.
Links_OOS: CSide
ISTb
Bsy Passed
Do
step 11
step 19
Do
step 14
step 15
0 , PSide
1