5-20 RSC-M alarm clearing procedures
PM RSC-M/RCO2
critical
(continued)
30
31
32
33
34
297-8223-550 Standard 04.02 November 2000
If TST
fails
To return the inactive RCO2 unit to service, type
>rts unit unit_no
and press the Enter key.
where
unit_no
is the number of the RCO2 tested in step 29
If RTS
passes
fails
Observe the card listing shown on the MAP display.
Example of a MAP response:
SITE
FLR
RPOS BAY_ID
RSCS0
01
RSCS0
01
RSCS0
01
RSCS0
01
RSCS0
01
If you
replaced all the cards on the list
did not replace all the cards on the list
Determine if the NTMX82 circuit card was replaced.
If you
replaced the NTMX82 circuit card
did not replace the NTMX82 circuit card
Go to the card replacement procedure for the NTMX82 circuit card in the Card
Replacement Procedures section of this document. When you finish the card
replacement procedures, go to step 23 of this procedure.
Go to the card replacement procedure in Card Replacement Procedures for
the next card on the card list. When you finish the card replacement
procedures, go to step 29 of this procedure.
Do
step 31
Do
step 37
step 36
SHF
A00 RSCM
00
32
A00 RSCM
00
32
A00 RSCM
00
32
A00 RSCM
00
32
A00 RSCM
00
32
DESCRIPTION
SLOT
EQPEC
RCO2 :
000
:03
RCO2 :
000
:08
RCO2 :
000
:11
RCO2 :
000
:15
RCO2 :
000
:17
Do
step 32
step 34
Do
step 36
step 33
MX77
MX76
MX73
MX74
MX73