8-22 RSC-M trouble isolation and correction
of long term failure counters is allowed from this level. The last diagnostic
failure time is the time of the last diagnostic failure that occurred on the unit.
The command string QUERYPM DIAGHIST provides a summary of
diagnostic failures and cards reported as hardware faults. This summary is the
same as the format that the command string DISP DIAGHIST displays. The
MAP responses in this text are for example purposes only.
If the requested PM is not supported, the following message appears:
Diagnostic history is not supported
for this PM type.
If a unit of the peripheral does not have diagnostic failures or card faults, the
system displays the following:
No failures recorded.
Three optional parameters are added to this option:
The following are examples of the command string QUERYPM DIAGHIST
used with and without optional parameters:
>MAPCI;MTC;PM;POST RCO2 0; QUERYPM DIAGHIST
297-8223-550 Standard 04.02 November 2000
reset
— allows long term failure counters to be reset to zero. The system
generates a PM601 log that record a summary of the long-term failure
counters before the counters are reset.
diag
— displays the short- and long-term failure counts of the diagnostics that
each unit of an XPM fails. This parameter does not contain card
information.
card
— displays the short and long term failure counts of the cards on each unit
of the XPM that the log reports as hardware failures. This parameter
does not contain diagnostic information.
Note 1: The reset parameter is not specified for routine use. Reset
changes long term failure counters to zero.
Note 2: The card parameter provides an asterisk (*) beside any card that
a diagnostic on the mate unit in the XPM reports.