Nortel DMS 100 Series Maintenance Manual page 311

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

RCO2 0
Long–Term Failure (LTF) last reset: 95/03/24 08:44:53
UNIT 0 Short–Term Failure (STF) last reset: 95/03/29
12:28:23
Last diagnostic failure: 95/03/29 12:47:55
DIAGLIST
CPM AUD: Total failures
FAC AUD: Total failures
EXTDIAG: Total failures
UNIT 1 Short–Term Failure (STF) last reset: 95/03/28
16:12:15
Last diagnostic failure: 95/03/28 15:41:45
DIAGLIST
DCHIALB: Total failures
EXTDIAG: Total failures
FAC AUD: Total failures
CPM AUD: Total failures
This response is the default information for the DIAGHIST option. The
default response identifies the failed diagnostics and associated cards. This
display indicates that on unit 0, the CPMAUD failed one time since the last
time unit 0 gained activity. The 1 in the STF column indicates this failure. The
last time the unit gained activity was at 12:28 a.m. on 3/29. The numbers
below the 1 indicate the cards involved. The CPMAUD failed a total of four
times since the LTF reset time. The last reset time was at 8:44 a.m. on 3/24.
A single test can cause one or more diagnostic failures. The test can cause at
least zero associated cards. The sum of card counts from this display cannot
be the accurate number of times a diagnosis fails. Also, the cards can be on
either unit. Only specified diagnostics report failures on the mate unit. This
display shows cards on the same unit the diagnostic runs on.>QUERYPM
DIAGHIST DIAG
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
RSC-M trouble isolation and correction 8-23
CARDLIST
:NTMX79
:NTMX77
:NTMX79
:NTMX79
CARDLIST
:NTMX77
:NTMX79
:NTMX79
:NTMX76
:NTMX77
:NTMX79
STF
LTF
1
4
1
4
1
3
0
3
0
3
0
3
0
3
STF
LTF
0
6
0
1
0
5
0
4
0
4
0
1
0
1
0
1
0
1
0
1