20. Specifications

20.4.Acquisition Data Output

Record a part of or all recording data. In addition, the data can be saved in a different format.
Where to output
Recording Part
File

20.5.Standard Function

Function Name
Screen Copy
Saving Screen Image
Paper Feeding
List View
Initialization
When Using an Optional RS-232C
and Recommended UPS
Saving and loading data and
setting information
System Check
Test Print
Data No. setting
Backlight Auto Off
Alarm/Error Displaying Function
Memory Space Changing Function

20.6.Interface

20.6.1. LAN (Standard)

Communication speed: 100-BASE-T
Spec
*A category 5 LAN cable must be used.

20.6.2. USB (Standard)

Spec
USB port x 2, USB 1.1.

20.6.3. TRIG IN/TRIG OUT (Standard)

TRIG IN: 0 to 5 voltage input (LOW level: 0.5V or less, HIGH level: 4.5V or more)
Spec
TRIG OUT: When a trigger condition is met, TTL level voltage signals (Active Low,
Pulse width approx, 10ms) is output.
Output Format
Waveform
Narrowing and Extending the time axis of a wave form is
Recording
available.
Extending 1/1 (standard), 2, 5, 10, 20, 50, and 100 times
Narrowing 1/2, 1/5, 1/10, 1/20, 1/50, 1/100, 1/200, 1/500,
1/1000, 1/2000, 1/5000, and 1/10000
* Standard (one time) = 100data/div
X-Y Recording
Binary
All specified range of data is saved.
CSV
Saving data internal 1, 2, 5, 10, 20, 50, 100, 200, 500, and
1000 steps
Hard copy of displayed screen with recording part is available.
Saving to a file in bitmap format is available.
While pushing Paper Feeding key, preliminary feeding of a
recording paper is available.
The information of current settings can be listed.
A main unit can be reset to the default setting.
When recovering from power failure or power interruption, the
original state can be automatically restored.
Saving memory recording data and maximum four setting
conditions of a main unit can be saved to media.
A main unit can be self-checked.
Printing state can be confirmed.
Any measuring data number can be assigned to each
measuring data.
If no settings and operations are made for a fixed time (from 1
to 60 minutes) with the operation panel key or the touch panel
key, the backlight is automatically turned off
When an error occurs (recording paper empty, release of
thermal head connecting, and abnormal rise of thermal head
temperature), an alarm can be raised.
An error window is also displayed.
Restricting the number of channels used for memory
recording enable increasing memory space per channel.
Output Method
Function Details
Communication Protocol: TCP/IP
20-12
RA2300A Recorder (7001754-R01)