20.2.2. Recording Function

The followings are common functions of printing on recording papers regardless of an recording
mode.
Function
Scale Print
Trigger Information
Data Information
User Page
annotation
Channel Annotation
Signal Name
Measurement
Information

20.2.3. Amp Unit Function

The followings are functions of recording and monitoring related to an amp unit.
Function
Physical
Quantity
Conversion
Wide Scale
Channel
Discrimination
Signal Name
Base Line Setting
Zero Position
RA2300A Recorder (7001754-R01)
369.5±2(W)×164.5±2(H)×301±2(D)mm (including rubber legs)
Excluding protrusion (knurl screws in an Amp part and a jog dial)
Approx. 7.0kg Main body only (excluding Amps and options)
Approx. 7.8kg with options and 4 units of 2CH High -resolution DC amps
Weight
installed (including RS-232C, AC Bridge Power Supply, and Recording
paper.
±30 seconds error per month (ambient temperature 25 degrees
centigrade
A clock and setting information are backed up by built-in battery.
Backup
(manganese dioxide primary battery) Battery life: approx. five years
(ambient temperature 25 degrees centigrade)
waveform
X-Y
-
-
-
-
-
Record
Monitor
-
-
Explanation
Scales
are
automatically
sensitivity and base line positions, and then printing is
available before or at the end of recording.
After printing a trigger point as the arrow mark (↓), the
occurrence date and time of trigger can be printed
together.
Records can be printed with information such as
recording mode, measuring date and starting time,
data No. , trigger conditions (trigger points and trigger
date and time), sampling speed, paper feeding
speed, and time axis.
An annotation is printed on records. Maximum 64
characters x 108 rows can be specified.
Channel information is printed on records.
An annotation per signal is printed before waveform
records. Maximum 31 characters can be specified.
An annotation is printed before waveform information.
Maximum 64 characters x 108 rows can be specified.
Explanation
The waveform of an amp unit and full scale of display
output can be changed, and Input signals can be
configured in physical quantity or an arbitrary unit.
Full scale can be changed to display or record the all
range possible to be input at standard sensitivity.
Channel No. can be printed near waveform records.
Any input character can be printed. Maximum 8
characters x 1 row.
The base line thickness of a waveform record can be
specified per channel.
Zero position can be specified at 5%, 10%, or 0.05%
step of full scale
20-5