H: Terminals; H1: Digital Inputs - Omron Q2V Series Technical Manual

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

11.9 H: TERMINALS

11.9

H: TERMINALS

H1: DIGITAL INPUTS

No.
Name
(Hex.)
H1-01
DI1 Function Selection
(0438)
H1-02
DI2 Function Selection
(0439)
H1-03
DI3 Function Selection
(0400)
H1-04
DI4 Function Selection
(0401)
H1-05
DI5 Function Selection
(0402)
H1-06
DI6 Function Selection
(0403)
H1-07
DI7 Function Selection
(0404)
H1-21
DI1 Funct.Sel 2
(0B70)
H1-22
DI2 Funct.Sel 2
(0B71)
H1-23
DI3 Funct.Sel 2
(0B72)
H1-24
DI4 Funct.Sel 2
(0B73)
H1-25
DI5 Funct.Sel 2
(0B74)
H1-26
DI6 Funct.Sel 2
(0B75)
H1-27
DI7 Funct.Sel 2
(0B76)
H1-40
Mbus 15C0h b0 Input
Function
(0B54)
H1-41
Mbus 15C0h b1 Input
Function
(0B55)
H1-42
Mbus 15C0h b2 Input
Function
(0B56)
348
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function for MFDI terminal DI1.
Note:
The default setting is 0 when the drive is initialized for 3-Wire Initialization [A1-03
= 3330].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function for MFDI terminal DI2.
Note:
The default setting is 0 when the drive is initialized for 3-Wire Initialization [A1-03
= 3330].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function for MFDI terminal DI3.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function for MFDI terminal DI4.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function for MFDI terminal DI5.
Note:
When you initialize the drive for 3-Wire Initialization [A1-03 = 3330], the default
setting is 5.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function for MFDI terminal DI6.
Note:
When you initialize the drive for 3-Wire Initialization [A1-03 = 3330], the default
setting is A.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function for MFDI terminal DI7.
Note:
When you initialize the drive for 3-Wire Initialization [A1-03 = 3330], the default
setting is B.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the second function for MFDI terminal DI1.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the second function for MFDI terminal DI2.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the second function for MFDI terminal DI3.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the second function for MFDI terminal DI4.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the second function for MFDI terminal DI5.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the second function for MFDI terminal DI6.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the second function for MFDI terminal DI7.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Selects MFDI function assigned to bit 0 of the Modbus register 15C0 (Hex.).
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Selects MFDI function assigned to bit 1 of the Modbus register 15C0 (Hex.).
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Selects MFDI function assigned to bit 2 of the Modbus register 15C0 (Hex.).
Default
(Range)
1
(1 - 4, 6 - 19F)
2
(1 - 4, 6 - 19F)
24
(0 - 19F)
7B
(0 - 19F)
A
(0 - 19F)
B
(0 - 19F)
6
(0 - 1FF)
0
(1 - 4, 6 - 19F)
0
(1 - 4, 6 - 19F)
0
(1 - 4, 6 - 19F)
0
(1 - 4, 6 - 19F)
0
(1 - 4, 6 - 19F)
F
(1 - 19F)
0
(1 - 4, 6 - 19F)
0
(1 - 4, 6 - 19F)
0
(1 - 4, 6 - 19F)
0
(1 - 4, 6 - 19F)
SIEPCYEUOQ2V01A Q2V Technical Manual
Ref.
567
567
567
567
567
567
568
568
568
568
568
568
569
569
569
569
569

Advertisement

Table of Contents
loading

Table of Contents