12.7 H: TERMINALS
H2-29: Compare2 Hysteresis
No.
Name
(Hex.)
H2-29
Compare2 Hysteresis
(1549)
Note:
For information on the comparator function, refer to
H2-30: Compare2 On-Delay Time
No.
Name
(Hex.)
H2-30
Compare2 On-Delay Time
(154A)
Note:
For information on the comparator function, refer to
H2-31: Compare2 Off-Delay Time
No.
Name
(Hex.)
H2-31
Compare2 Off-Delay Time
(154B)
Note:
For information on the comparator function, refer to
H2-32: Compare1 Filter Time
No.
Name
(Hex.)
H2-32
Compare1 Filter Time
(159A)
Note:
For information on the comparator function, refer to
H2-33: Compare1 Protection Selection
No.
Name
(Hex.)
H2-33
Compare1 Protection
Selection
(159B)
0 : Ramp->Stop
The drive ramps the motor to stop in the deceleration time. The output terminal set for Fault [H2-01 to H2-03 =
3] activates.
1 : Coast->Stop
The output turns off and the motor coasts to stop. The output terminal set for Fault [H2-01 to H2-03 = 3]
activates.
2 : Fast Stop (C1-09)
The drive stops the motor in the deceleration time set in C1-09 [Fast Stop Time]. The output terminal set for Fault
[H2-01 to H2-03 = 3] activates.
3 : Alarm Only
The keypad shows CP1 and the drive continues operation at the current frequency reference.
Note:
The output terminal set to Alarm [H2-01 to H2-03 = 4] activates.
4 : Low Speed (L8-19)
592
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the hysteresis level for comparator 2 as a percentage of the full scale analog output for the
monitor selected in H2-26 [Compare2 Mon.Selection].
3C: Comparator 1 on page 605
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the on-delay time for comparator 2.
3C: Comparator 1 on page 605
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the off-delay time for comparator 2.
3C: Comparator 1 on page 605
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the time constant that is applied to the primary delay filter used for the analog output of the
monitor selected with H2-20 [Compare1 Mon.Selection].
3C: Comparator 1 on page 605
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets drive operation when it detects CP1 [Comparator1 Limit Fault].
Description
and
3D: Comparator 2 on page
Description
and
3D: Comparator 2 on page
Description
and
3D: Comparator 2 on page
Description
and
3D: Comparator 2 on page
Description
SIEPCYEUOQ2V01A Q2V Technical Manual
Default
(Range)
0.0%
(0.0 - 10.0%)
605.
Default
(Range)
0.0 s
(0.0 - 600.0 s)
605.
Default
(Range)
0.0 s
(0.0 - 600.0 s)
605.
Default
(Range)
0.0s
(0.0 - 10.0 s)
605.
Default
(Range)
4
(0 - 4)

Advertisement