11.17 Parameters that Change from the Default Settings with A1-02 [Control Method]

11.17 Parameters that Change from the Default Settings with
A1-02 [Control Method]
The values for the parameters in these tables depend on the values for parameter A1-02. When you change the
setting for A1-02, the default settings will change.
No.
b2-01
ZSpd/DCI Threshold
b2-04
DCInj Time@Stop
b3-01
SpSrch@Start Selection
SpSrch Deactivation
b3-02
Current
Speed ACR PGain for
b3-08
Estimation
Speed ACR ITime for
b3-09
Estimation
Speed Bi-Directional
b3-14
Search
b5-15
Sleep Start Level
b6-01
Dwell Ref.@Start
b6-03
Dwell Ref@Stop
b8-02
eSave Ctrl Gain
b8-03
eSave Filter Time
b8-19
eSave Search Frequency
C1-11
Ac/Dec Switch Frequency
C2-01
Jerk@Start of Accel
C3-01
Slip Comp Gain
C3-02
Slip Comp Delay Time
C4-01
Trq Comp Gain
C4-02
Trq Comp Delay Time
C5-01
ASR PGain 1
C5-02
ASR ITime 1
C5-03
ASR PGain 2
C5-04
AASR ITime 2
C5-06
ASR Delay Time
ASR Gain Switch
C5-07
Frequency
Carrier Frequency
C6-02
Selection
d3-01
Jump Frequency 1
d3-02
Jump Frequency 2
d3-03
Jump Frequency 3
d3-04
Jump Frequency Width
E1-04
Max Output Frequency
E1-05
Max Output Voltage
E1-06
Base Frequency
E1-07
Mid A Frequency
E1-08
Mid A Voltage
E1-09
Min Output Frequency
SIEPCYEUOQ2V01A Q2V Technical Manual
Table 11.1 A1-02 = 0, 2 [V/f Control, OLVector]
Name
Range
0.0 - 10.0
0.00 - 10.00
0 - 1
0 - 200
0.00 - 6.00
0.0 - 1000.0
0 - 1
0.0 - 400.0
0.0 - 400.0
0.0 - 400.0
0.0 - 10.0
0.00 - 10.00
10 - 300
0.0 - 400.0
0.00 - 10.00
0.0 - 2.5
0 - 10000
0.00 - 2.50
0 - 10000
0.00 - 300.00
0.000 - 60.000
0.00 - 300.00
0.000 - 10.000
0.000 - 0.500
0.0 - 400.0
1 - F
0.0 - 400.0
0.0 - 400.0
0.0 - 400.0
0.0 - 20.0
*2 *3
40.0 - 400.0
*5
0.0 - 255.0
*3
0.0 - 400.0
*3
0.0 - 400.0
*5
0.0 - 255.0
*3
0.0 - 400.0
Control Method (A1-02 Setting)
Unit
V/f
(0)
0.1 Hz
0.5
0.01 s
0.50
1
0
1%
120
*1
0.01
0.50
0.1 ms
2.0
1
0
0.1 Hz
0.0
0.1 Hz
0.0
0.1 Hz
0.0
0.1
-
0.01 s
-
1 Hz
100
0.1 Hz
0.0
0.01 s
0.20
0.1
0.0
1 ms
2000
0.01
1.00
1 ms
200
0.01
-
0.001 s
-
0.01
-
0.001 s
-
0.001 s
-
0.1 Hz
0.0Hz
*2
1
1
0.1 Hz
0.0
0.1 Hz
0.0
0.1 Hz
0.0
0.1 Hz
1.0
*4
0.1 Hz
60.0
*4
0.1 V
200.0
*4
0.1 Hz
60.0
*4
0.1 Hz
3.0
*4
0.1 V
15.0
*4
0.1 Hz
1.5
OLV
(2)
0.5
0.50
0
100
*1
0.50
2.0
0
0.0
0.0
0.0
0.7
0.50
100
0.0
0.20
1.0
200
1.00
20
-
-
-
-
-
0.0Hz
*2
1
0.0
0.0
0.0
1.0
60.0
200.0
60.0
11
3.0
11.0
0.5
403