F7: Ethernet - Omron Q2V Series Technical Manual

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

11.8 F: OPTIONS
No.
Name
(Hex.)
F6-55
DNet Baud Monitor
(03C6)
F6-56
DNet Speed Scale Factor
(03D7)
F6-57
DNet Current Scale
Factor
(03D8)
F6-58
DNet Torque Scale
Factor
(03D9)
F6-59
DNet Power Scaling
(03DA)
F6-60
DNet Voltage Scale
(03DB)
F6-61
DNet Time Scale
(03DC)
F6-62
DNet Heartbeat Interval
(03DD)
F6-63
DNet Network MAC ID
(03DE)
F6-64 to F6-67
DynOut.Ass109 P1 to P4
(03DF - 03E2)
F6-68 to F6-71
DynIn.Ass159 P1 to 4
(03E3, 03E4,
03C7, and
03C8)
F6-72
PowerLink Address
(081B)

F7: ETHERNET

No.
Name
(Hex.)
F7-01
IP Address 1
(03E5)
F7-02
IP Address 2
(03E6)
F7-03
IP Address 3
(03E7)
344
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to see the actual DeviceNet communications speed using the keypad.
This parameter functions as a monitor only.
0 : 125 kbps
1 : 250 kbps
2 : 500 kbps
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the speed scale for DeviceNet communication.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the current scale of the DeviceNet communication master.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the torque scale of the DeviceNet communication master.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the power scale of the DeviceNet communication master.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the voltage scale of the DeviceNet communication master.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the time scale of the DeviceNet communication master.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the heartbeat for DeviceNet communication. Set this parameter to 0 to disable the
heartbeat function.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function to see the actual DeviceNet MAC address using the keypad. This
parameter functions as a monitor only.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets Configurable Outputs 1 to 4 written to the Modbus register.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets Configurable Inputs 1 to 4 written to the Modbus register.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the node ID for PowerLink communication.
Note:
Be sure to set an address that is different than all other node addresses. Do not set
this parameter to 0.
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the first octet of the IP Address for the device that is connecting to the network.
Restart the drive after you change this parameter.
Note:
When F7-13 = 0 [Addr Mode@Startup = Static]:
• Use parameters F7-01 to F7-04 to set the IP Address. Be sure to set a different IP
address for each drive on the network.
• Also set parameters F7-01 to F7-12.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the second octet of the IP Address for the device that is connecting to the network.
Restart the drive after you change this parameter.
Note:
When F7-13 = 0 [Addr Mode@Startup = Static]:
• Use parameters F7-01 to F7-04 to set the IP Address. Be sure to set a different IP
address for each drive on the network.
• Also set parameters F7-01 to F7-12.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the third octet of the IP Address for the device that is connecting to the network.
Restart the drive after you change this parameter.
Note:
When F7-13 = 0 [Addr Mode@Startup = Static]:
• Use parameters F7-01 to F7-04 to set the IP Address. Be sure to set a different IP
address for each drive on the network.
• Also set parameters F7-01 to F7-12.
Default
(Range)
0
(0 - 2)
0
(-15 - +15)
0
(-15 - +15)
0
(-15 - +15)
0
(-15 - +15)
0
(-15 - +15)
0
(-15 - +15)
0
(0 - 10)
0
(0 - 63)
0000h
(0000h - FFFFh)
0000h
(0000h - FFFFh)
0
(0 - 255)
Default
(Range)
192
(0 - 255)
168
(0 - 255)
1
(0 - 255)
SIEPCYEUOQ2V01A Q2V Technical Manual