10.10 Peripheral Devices and Options

These tables show the available peripheral devices and options for the drive. Contact the manufacturer or your
nearest sales representative to make an order.
• Selection: Refer to the drive catalog for information about available products.
• Installation and wiring: Refer to the instruction manual for each option.
Name
AC reactor
LR3 series and ALR3 series
Braking Resistor
ERF-150WJ Series
Residual Current Monitoring/
NV and NS series
Detection (RCM/RCD)
Molded-Case Circuit Breaker
NF series
(MCCB)
Input Side Magnetic Contactor
SC series
(MC)
Name
Heatsink External Mounting Kit
ZPSA-GA50Vx-x
ZPZ-GA50Vx
DIN Rail Attachment
EZZ08122D
Communication Option Case
JOHB-Q2V
Name
Q2edit
Q2dev
Name
Model
EtherNet/IP
SI-EN3
PROFINET
SI-EP3
EtherCAT
SI-ES3
Powerlink
SI-EL3
SIEPCYEUOQ2V01A Q2V Technical Manual
Table 10.34 Main Circuit Options
Model
To improve the drive input power factor.
• To prevent damage to the drive when the power supply capacity is large. You must only use this option
when the power supply capacity is more than 600 kVA.
• To decrease harmonic current.
• To improve the power supply total power factor.
To decrease the regenerative energy of the motor and decrease the deceleration time (duty cycle of 3%
ED). You must also use the installation attachment.
To prevent short circuit damage to the power supply system, provide overload protection for wiring,
prevent electrical shock, and provide ground fault protection against earth leakage fires.
Note:
• You can use a molded-case circuit breaker as a replacement for an RCM/RCD that is upstream in the
power supply system.
• When you use a high frequency RCM/RCD at the power input side of the drive, make sure that each
drive has a minimum cumulative sensitivity amperage of 30 mA.
To prevent short circuit damage to the power supply system and provide overload protection for wiring.
To prevent burn damage when connecting a braking resistor. This option fully opens the circuit between
the power supply and drive.
Table 10.35 Attachments
Model
Use this option to install the heatsink outside of the control panel.
To use a DIN rail to install the drive.
To install a communication option on a drive.
Table 10.36 Engineering Tools
Model
To use a PC to program drives and manage parameters.
-
To use a PC to do advanced drive programming.
-
Table 10.37 Communication Options
Intended Use
This option uses the host controller over EtherNet/IP communication to:
• Operate and stop the drive
• Set and view parameters
• Monitor output frequency, output current, and other statuses
This option uses the host controller over PROFINET communication to:
• Operate and stop the drive
• Set and view parameters
• Monitor output frequency, output current, and other statuses
This option uses the host controller over EtherCAT communication to:
• Operate and stop the drive
• Set and view parameters
• Monitor output frequency, output current, and other statuses
This option uses the host controller over Powerlink communication to:
• Operate and stop the drive
• Set and view parameters
• Monitor output frequency, output current, and other statuses

10.10 Peripheral Devices and Options

Intended Use
Intended Use
Intended Use
Document No.
TOBPC73060092
SIJPC73060092
TOBPC73060089
SIJPC73060089
Contact the manufacturer or your nearest
sales representative for more information.
Contact the manufacturer or your nearest
sales representative for more information.