C4: Torque Compensation - Omron Q2V Series Technical Manual

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

12.3 C: TUNING

C4: TORQUE COMPENSATION

Torque compensation is a function that increases voltage to increase output torque as compensation for
insufficient torque production at start-up or low-speed operation.
Voltage drops due to motor winding resistance cause torque generating voltage to decrease, which causes
insufficient torque. If the main circuit cable connecting the drive and motor is long, this can also cause insufficient
torque due to voltage drops.
Note:
Set the motor parameters and V/f pattern properly before setting C4 parameters.
C4-01: Trq Comp Gain
No.
Name
(Hex.)
C4-01
Trq Comp Gain
(0215)
RUN
For these control methods and states, adjust the setting value.
A1-02 [Control Method]
0 [V/f Control]
8 [EZ Vector]
Note:
• Adjust C4-01 to make sure that output current is not more than the drive rated current while the drive operates at low speed.
• When A1-02 = 2 [OLVector], do not change this parameter under normal conditions. Torque accuracy will decrease.
• When A1-02 = 5 [PM OLVector], do not change this parameter under normal conditions. Setting this value too high can cause
overcompensation and motor oscillation.
• When A1-02 = 8 [EZ Vector], you cannot change this parameter during drive run.
C4-02: Trq Comp Delay Time
No.
Name
(Hex.)
C4-02
Trq Comp Delay Time
(0216)
RUN
Note:
If A1-02 = 8 [Control Method = EZ Vector], you cannot change the setting while the drive is running.
Set this parameter in these conditions:
• If there is vibration in the motor, increase the setting.
• If the motor speed or motor torque response is too slow, decrease the setting.
C4-03: Trq Comp@FWD Start
No.
Name
(Hex.)
C4-03
Trq Comp@FWD Start
(0217)
The torque compensation function is performed using the time constant set in C4-05 [Trq Comp Time].
This is available only when you start the motor with the forward command. Set this parameter to 0.0 to disable
this function.
C4-04: Trq Comp@REV Start
No.
Name
(Hex.)
C4-04
Trq Comp@REV Start
(0218)
498
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the gain for the torque compensation function. Use this parameter value for motor 1 when
operating multiple motors.
Status
Torque is not sufficient during low-speed operation of 10 Hz or less.
There is vibration in the motor or the motor hunts when operating the
drive with a light load.
The cable length between the drive and motor is too long.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the torque compensation delay time. Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Set the amount of torque reference for forward start as a percentage of the motor rated torque.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the amount of torque reference for reverse start as a percentage of the motor rated torque.
Description
Increase the setting in 0.05-unit increments.
Decrease the setting in 0.05-unit decrements.
Increase the setting in 0.05-unit increments.
Description
Description
Description
SIEPCYEUOQ2V01A Q2V Technical Manual
Default
(Range)
Determined by A1-02
(0.00 - 2.50)
Adjustment
Default
(Range)
Determined by A1-02
(0 - 60000 ms)
Default
(Range)
0.0%
(0.0 - 200.0%)
Default
(Range)
0.0%
(-200.0 - 0.0%)

Advertisement

Table of Contents
loading