Omron Q2V Series Technical Manual page 156

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

5.2 European Standards
Model
Terminal
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
4038
-, +1, +2
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
4044
-, +1, +2
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
4060
-, +1, +2
B1, B2
*1
Remove insulation from the ends of wires to expose the length of wire shown.
*2
If you turn on the internal EMC filter, the leakage current of the drive will be more than 3.5 mA. Use these closed-loop crimp
terminals or equivalent to connect a protective ground wire that has a minimum cross-sectional area of 10 mm
• 8-4NS from JST Mfg. Co., Ltd.
• R8-4S from NICHIFU Co.,Ltd.
Connect a Fuse to the Input Side (Primary Side)
The drive circuit protection must comply with EN 61800-5-1:2007 for protection against a short circuit in the
internal circuitry. Connect semiconductor protection fuses on the input side for branch circuit protection.
WARNING! Electrical Shock Hazard. After the drive blows a fuse or trips an RCM/RCD, do not immediately energize the drive
or operate peripheral devices. Wait for the time specified on the warning label at a minimum and make sure that all indicators
are OFF. Then check the wiring and peripheral device ratings to find the cause of the problem. If you do not know the cause of
the problem, contact the manufacturer before you energize the drive or peripheral devices. If you do not fix the problem before
you operate the drive or peripheral devices, it can cause serious injury or death.
Three-Phase 200 V Class
Table 5.2 Factory-Recommended Branch Circuit Protection: Three-Phase 200 V Class
Semiconductor Protection Fuse Rated Current
Drive Model
2001
2002
2004
156
Recommended Gauge
Applicable Gauge
mm
2
10
6
16
4
10
16
10
16
6
10
25
16
25
10
10
Manufacturer: EATON/Bussmann
FWH-25A14F
FWH-25A14F
FWH-25A14F
Wire Stripping
*1
Length
mm
2
mm
4 - 16
10
2.5 - 10
10
4 - 25
18
2.5 - 6
10
6 - 16
-
4 - 25
18
4 - 16
18
6 - 25
18
4 - 10
10
6 - 16
-
6 - 35
18
4 - 25
18
6 - 35
18
2.5 - 16
10
6 - 16
-
Drive Model
2006
2008
2010
Tightening Torque
Terminal Screw
N∙m (in∙lb)
1.5 - 1.7
M4
(13.5 - 15)
1.5 - 1.7
M4
(13.5 - 15)
2.3 - 2.5
M5
(19.8 - 22)
1.5 - 1.7
M4
(13.5 - 15)
5.4 - 6.0
M6
(47.8 - 53.1)
2.3 - 2.5
M5
(19.8 - 22)
2.3 - 2.5
M5
(19.8 - 22)
2.3 - 2.5
M5
(19.8 - 22)
1.5 - 1.7
M4
(13.5 - 15)
5.4 - 6.0
M6
(47.8 - 53.1)
• ≤ 25 mm
2.3 - 2.5
(19.8 - 22)
M5
• 35 mm
2
4.1 - 4.5
(36 - 40)
2.3 - 2.5
M5
(19.8 - 22)
• ≤ 25 mm
2.3 - 2.5
(19.8 - 22)
M5
• 35 mm
2
4.1 - 4.5
(36 - 40)
1.5 - 1.7
M4
(13.5 - 15)
5.4 - 6.0
M6
(47.8 - 53.1)
2
(copper wire).
Semiconductor Protection Fuse Rated Current
Manufacturer: EATON/Bussmann
FWH-25A14F
FWH-70B
FWH-70B