B6: Dwell Function; B8: Energy Saving - Omron Q2V Series Technical Manual

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

No.
Name
(Hex.)
b5-90
EZsleep Unit
(0B90)
b5-91
EZsleep Min Spd
(0B91)
RUN
b5-92
EZsleep Level
(0B92)
RUN
b5-93
EZsleep Time
(0B93)
RUN
b5-94
EZsleep Wake Level
(0B94)
RUN
b5-95
EZsleep Wake Mode
(0B95)
b5-96
EZsleep Wake Time
(0B96)
RUN

b6: DWELL FUNCTION

No.
Name
(Hex.)
b6-01
Dwell Ref.@Start
(01B6)
b6-02
Dwell Time@Start
(01B7)
b6-03
Dwell Ref@Stop
(01B8)
b6-04
Dwell Time@Stop
(01B9)

b8: ENERGY SAVING

No.
Name
(Hex.)
b8-01
eSave Ctrl Selection
(01CC)
b8-02
eSave Ctrl Gain
(01CD)
RUN
Expert
b8-03
eSave Filter Time
(01CE)
RUN
Expert
b8-04
eSave Coef. Value
(01CF)
Expert
SIEPCYEUOQ2V01A Q2V Technical Manual
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the measurement units for b5-91 [EZsleep Min Spd] and b5-92 [EZsleep Level].
0 : rpm
1 : 0.1Hz units
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the minimum speed for the EZ Sleep/Wakeup function. This parameter uses the
largest value from b5-91, b5-34 [PID Out Low Limit Level], and d2-02 [FRef Lower
Limit].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the value that the output frequency or motor speed must be less than for longer than
b5-93 [EZsleep Time] to enter Sleep Mode.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the length of time that the output frequency or motor speed must be less than b5-92
[EZsleep Level] to enter Sleep Mode.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the level at which the drive resumes operation when exiting Sleep Mode.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the wake-up mode to use when exiting Sleep Mode.
0 : Setpoint Delta
1 : Absolute
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the EZ Wake-up time.
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the output frequency that the drive will hold momentarily when the motor starts.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the length of time that the drive will hold the output frequency when the motor
starts.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the output frequency that the drive will hold momentarily when ramping to stop the
motor.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the length of time for the drive to hold the output frequency when ramping to stop
the motor.
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the Energy-saving control function.
0 : Disabled
1 : Enabled
2 : Search Enabled
Note:
When A1-02 = 6 [Control Method = PM AOLVector], you can only select setting 2
in Expert Mode.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the gain for Energy-saving control.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the responsiveness for Energy-saving control.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the Energy-saving control coefficient to maintain maximum motor efficiency. The
default setting is for Yaskawa motors.
11.4 b: APPLICATION
Default
Ref.
(Range)
0
481
(0, 1)
0.0 Hz or 0 min
-1
(r/min)
481
(0.0 to 590.0 Hz or 0 to
35400 min
-1
(r/min))
0.0 Hz or 0 min
-1
(r/min)
481
(0.0 to 590.0 Hz or 0 to
35400 min
-1
(r/min))
5.0 s
481
(0.0 - 1000.0 s)
0.00%
481
(0.00 - 600.00%)
0
482
(0, 1)
1.0 s
482
(0.0 - 1000.0 s)
Default
Ref.
(Range)
0.0
482
(Determined by A1-02)
0.0 s
483
(0.0 - 10.0 s)
0.0
483
(Determined by A1-02)
0.0 s
483
(0.0 - 10.0 s)
Default
Ref.
(Range)
0
483
(0 - 2)
Determined by A1-02
483
(0.0 - 10.0)
Determined by A1-02,
484
C6-01 and o2-04
(0.00 - 10.00 s)
Determined by C6-01,
484
E2-11, and o2-04
(0.00 - 655.00)
325
11