Omron Q2V Series Technical Manual page 352

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

11.9 H: TERMINALS
Setting Value
Function
67
SpdSrch Fmax
68
SpdSrch Fref
6A
PID Disable
71
PID I Reset
72
PID I Hold
75
PID SS Cancel
76
PID InLv Select
77
PID SP 1
78
PID SP 1
7A
PID BiDir
7B
Fault Reset
7C
Prg Lock
7D
Drive OH2
7E
Node Setup
7F
Comms Test
90 - 96
Q2pack DI1 to 7
9F
Q2pack Disable
101 to 19F
Inverse Input of 1 to 9F
352
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to start speed search using an external reference although b3-01 = 0 [SpSrch@Start Selection =
Disabled].
Note:
The drive will detect oPE03 [Multi-Function Input Setting Err] when H1-xx = 67 and 68 are set at the same
time.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to start speed search using an external reference although b3-01 = 0 [SpSrch@Start Selection =
Disabled].
Note:
The drive will detect oPE03 [Multi-Function Input Setting Err] when H1-xx = 67 and 68 are set at the same
time.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the command to disable PID control when b5-01 = 1 [PID Enable = Enabled].
ON : PID control disabled
OFF : PID control enabled
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the command to reset and hold the PID control integral to 0 when the terminal is ON.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the command to hold the integral value of the PID control while the terminal is activated.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the PID soft starter function.
ON : No
OFF : Yes
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the command to turn the terminal ON and OFF to switch the PID input level (polarity).
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Set this function and H1-xx = 78 [PID SP 2] together. Sets the function to switch the PID setpoint to b5-58 to b5-
60 [PID Setpoints 2 to 4].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Set this function and H1-xx = 77 [PID SP 1] at the same time. Sets the function to switch the PID setpoint to b5-58
to b5-60 [PID Setpoints 2 to 4].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets operation of the PID Bi-Directional function.
ON : Enabled
OFF : Disabled
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the command to reset the current fault when the Run command is inactive.
Note:
The drive ignores the fault reset command when the Run command is active. Remove the Run command
before trying to reset a fault.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the command to prevent parameter changes when the terminal is OFF.
ON : Programming Lockout
OFF : Parameter Write Prohibit
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the drive to display an oH2 [Drive Overheat Warning] alarm when the input terminal is ON. The alarm does
not have an effect on drive operation.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function in CANopen communications to start the Node Setup function to set the drive node address from
the host controller.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Set the function for the drive to self-test RS-485 serial communications operation.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets digital inputs used with Q2pack. Refer to the Q2pack online manual for more information.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets operation of the Q2pack program saved in the drive.
ON : No
OFF : Yes
Note:
Set A1-07 = 2 [Q2pack Enable = With DI] to enable this function.
Sets the function of the selected MFDI to operate inversely. To select the function, enter "1xx", where the "xx" is
the function setting value.
Note:
You cannot use inverse input for all functions. Refer to
Description
Table 12.38
for more information.
SIEPCYEUOQ2V01A Q2V Technical Manual
Ref.
584
584
584
584
584
585
585
585
585
585
585
586
586
586
586
586
586
586

Advertisement

Table of Contents
loading

Table of Contents