11.5

C: TUNING

C1: ACCEL / DECEL

No.
Name
(Hex.)
C1-01
Accel Time 1
(0200)
RUN
C1-02
Decel Time 1
(0201)
RUN
C1-03
Accel Time 2
(0202)
RUN
C1-04
Decel Time 2
(0203)
RUN
C1-05
Accel Time 3
(0204)
RUN
C1-06
Decel Time 3
(0205)
RUN
C1-07
Accel Time 4
(0206)
RUN
C1-08
Decel Time 4
(0207)
RUN
C1-09
Fast Stop Time
(0208)
RUN
C1-10
Ac/Dec Units
(0209)
C1-11
Ac/Dec Switch
Frequency
(020A)
C1-14
Ac/Dec Base Frequency
(0264)
RUN

C2: JERK CONTROL

No.
Name
(Hex.)
C2-01
Jerk@Start of Accel
(020B)
C2-02
Jerk@End of Accel
(020C)
C2-03
Jerk@Start of Decel
(020D)
C2-04
Jerk@End of Decel
(020E)
SIEPCYEUOQ2V01A Q2V Technical Manual
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the length of time to accelerate from zero to maximum output frequency.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the length of time to decelerate from maximum output frequency to zero.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the length of time to accelerate from zero to maximum output frequency.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the length of time to decelerate from maximum output frequency to zero.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the length of time to accelerate from zero to maximum output frequency.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the length of time to decelerate from maximum output frequency to zero.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the length of time to accelerate from zero to maximum output frequency.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the length of time to decelerate from maximum output frequency to zero.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the length of time that the drive will decelerate to zero for a Fast Stop.
Note:
• Decelerating too quickly can cause an ov [Overvoltage] fault that shuts off the
drive while the motor to coasts to a stop. Set a Fast Stop time in C1-09 that
prevents motor coasting and makes sure that the motor stops quickly and safely.
• When L2-29 = 1 [KEB Method = Single KEB1 Ride-Thru] and you do KEB Auto-
Tuning, the drive will automatically set C1-09. If you must not change the Fast
Stop time, do not do KEB Tuning.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the setting units for C1-01 to C1-08 [Accel Time 1 to Decel Time 4], C1-09 [Fast
Stop Time], L2-06 [KEB Decel Time], and L2-07 [KEB Accel Time].
0 : 0.01s
1 : 0.1s
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the frequency at which the drive will automatically change acceleration and
deceleration times.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the base frequency used to calculate acceleration and deceleration rates.
Description
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the S-curve acceleration time at start.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the S-curve acceleration time at completion.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the S-curve deceleration time at start.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the S-curve deceleration time at completion.

11.5 C: TUNING

Default
Ref.
(Range)
10.0 s
489
(0.0 - 6000.0 s)
10.0 s
490
(0.0 - 6000.0 s)
10.0 s
490
(0.0 - 6000.0 s)
10.0 s
490
(0.0 - 6000.0 s)
10.0 s
490
(0.0 - 6000.0 s)
10.0 s
490
(0.0 - 6000.0 s)
10.0 s
490
(0.0 - 6000.0 s)
10.0 s
491
(0.0 - 6000.0 s)
10.0 s
491
(0.0 - 6000.0 s)
1
491
(0, 1)
Determined by A1-02
491
(0.0 - 590.0 Hz)
0.0 Hz
492
(0.0 - 590.0 Hz)
Default
Ref.
(Range)
Determined by A1-02
494
(0.00 - 10.00 s)
0.20 s
494
(0.00 - 10.00 s)
0.20 s
494
(0.00 - 10.00 s)
0.00 s
494
(0.00 - 10.00 s)
327