12.7 H: TERMINALS
1: Forward Run
Setting Value
Function
1
Forward Run
ON : Forward Run
OFF : Run Stop
Note:
• Turning ON the Forward Run command terminal and the Reverse Run command terminal will cause alarm EF [FWD/REV Run
Command Input Error] and the motor will ramp to stop.
• Initialize the drive with a 2-wire sequence to set the Forward Run command to terminal DI1.
• This function will not operate at the same time as H1-xx = 3, 4 [Run Command, FWD/REV Cmd].
2: Reverse Run
Setting Value
Function
2
Reverse Run
ON : Reverse Run
OFF : Run Stop
Note:
• Turning ON the Forward Run command terminal and the Reverse Run command terminal will cause alarm EF [FWD/REV Run
Command Input Error] and the motor will ramp to stop.
• Initialize the drive with a 2-wire sequence to set the Reverse Run command to terminal DI2.
• This function will not operate at the same time as H1-xx = 3, 4 [Run Command, FWD/REV Cmd].
3: Run Command
Setting Value
Function
3
Run Command
ON : Run
OFF : Stop
Note:
This function will not operate at the same time as H1-xx = 1, 2 [Forward Run, Reverse Run].
4: FWD/REV Cmd
Setting Value
Function
4
FWD/REV Cmd
ON : Reverse
OFF : Forward
Note:
• You must input the Run command to rotate the motor.
• This function will not operate at the same time as H1-xx = 1, 2 [Forward Run, Reverse Run].
570
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the Forward Run command for 2-wire sequence 1. Set this function and H1-xx = 2 [Reverse Run] at the same time.
Figure 12.64 2-Wire Sequence Wiring Example
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the Forward Run command for 2-wire sequence 1. Set this function and H1-xx = 1 [Forward Run] at the same time.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the Run command for 2-wire sequence 2. Set this function and H1-xx = 4 [FWD/REV Cmd] at the same time.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the direction of motor rotation for 2-wire sequence 2. Set this function and H1-xx = 3 [Run Command] together.