12.9 n: SPECIAL
n8-49: Heavy Load Id Current
No.
Name
(Hex.)
Heavy Load Id Current
n8-49
(053C)
RUN
Expert
When you use an IPM motor, you can use the reluctance torque of the motor to make the motor more efficient and
help conserve energy.
When you operate an SPN motor, set this parameter to 0.
Adjust in the following situations.
• If the load is large and motor rotation is not stable, decrease the setting value.
• When you change E5: PM MOTOR SETTINGS, set n8-49 = 0, then adjust this parameter.
n8-50: Medium Load Iq Level (High)
No.
Name
(Hex.)
Medium Load Iq Level
n8-50
(High)
(053D)
Expert
n8-51: Ac/Dec Pull-In Current
No.
Name
(Hex.)
Ac/Dec Pull-In Current
n8-51
(053E)
Adjust in the following situations.
• When the motor does not smoothly because of large loads, increase the setting value in 5% increments.
• If too much current flows during acceleration, decrease the setting value.
Note:
When A1-02 = 8 [Control Method = EZ Vector], this parameter will always be in effect for speed ranges less than n7-10 [Pull-in
SwitchSpeed].
n8-54: Volt-Err Compensation Time
No.
Name
(Hex.)
Volt-Err Compensation
n8-54
Time
(056D)
Expert
Adjust this parameter in these conditions:
• If oscillation occurs at the time of start up, increase the setting value.
• If hunting occurs when operating at low speed, increase the setting value.
• If fast changes in the load cause hunting, increase the setting value in 0.1-unit increments. If you cannot stop
hunting, set n8-51 [Ac/Dec Pull-In Current] to 0% and set n8-54 to 0.00 s, and disable compensation for voltage
errors.
n8-55: Load Inertia
No.
Name
(Hex.)
Load Inertia
n8-55
(056E)
Adjust in the following situations.
• If torque and speed response is unsatisfactory, gradually increase the setting from 0.
• If the motor does not run smoothly, gradually increase the setting from 0.
688
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the d-axis current to that the drive will supply to the motor to run it at a constant speed with a
heavy load. Considers E5-03 [PM Mot Rated Current (FLA)] to be 100%. Usually it is not
necessary to change this setting.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the load current level at which heavy load control starts where E5-03 [PM Mot Rated Current
(FLA)] is 100%. Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the pull-in current allowed to flow during acceleration/deceleration as a percentage of the
motor rated current.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the time constant that the drive uses when adjusting for voltage errors.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the ratio between motor inertia and machine inertia.
Description
Description
Description
Description
Description
SIEPCYEUOQ2V01A Q2V Technical Manual
Default
(Range)
Determined by E5-01
(-200.0 - +200.0%)
Default
(Range)
80%
(50 - 255)
Default
(Range)
Determined by A1-02
(0 - 200%)
Default
(Range)
1.00 s
(0.00 - 10.00 s)
Default
(Range)
1
(1 - 4)