Omron Q2V Series Technical Manual page 326

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

11.4 b: APPLICATION
No.
Name
(Hex.)
b8-05
Power Det.Filter Time
(01D0)
Expert
b8-06
Srch Op.Volt Limit
(01D1)
Expert
b8-16
PM eSave Coef.Ki
(01F8)
Expert
b8-17
PM eSave Coef.Kt
(01F9)
Expert
b8-18
eSave d-Axis Filter Time
(01FA)
Expert
b8-19
eSave Search Frequency
(0B40)
Expert
b8-20
PM eSave Width for Test
(0B41)
Expert
b8-21
PM eSave Gain for Test
(0B42)
Expert
b8-22
PM eSave LPF Cutoff
Frq
(0B43)
Expert
b8-23
PM eSave Srch Limit
(0B44)
Expert
b8-24
PM eSave HiF Gain for
ACR
(0B45)
Expert
b8-25
PM eSave Srch Start
Level
(0B46)
Expert
b8-26
PM eSave Pwr SP
Setpoint
(0B47)
Expert
b8-28
OverExc Action
Selection
(0B8B)
Expert
b8-29
eSave Priority Mode
(0B8C)
326
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the time constant to measure output power.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the voltage limit for Search Operation as a percentage of the motor rated voltage.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets torque linearity. This parameter uses the Ki value from the motor nameplate.
Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets torque linearity. This parameter uses the Kt value from the motor nameplate.
Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the d-axis current reference filter time constant.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the frequency of Energy-saving control search operations. Usually it is not
necessary to change this setting.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the amplitude of Energy-saving control search operations.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the gain of Energy-saving control search operations.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the frequency of the filter used to extract the high-efficiency phase from search
operations. Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the search operations output limit. Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the gain for high-frequency current control.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the start level for search operations.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets a value to increase torque accuracy.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function for excitation operation.
0 : Disabled
1 : Enabled
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the priority of drive response between changes to the load or Energy-saving
control. Enable this to prioritize energy-saving control. Disable this to prioritize
tracking related to fast load changes, and prevent motor stall.
0 : Priority: Drive Response
1 : Priority: Energy Savings
Default
(Range)
20 ms
(0 - 2000 ms)
0%
(0 - 100%)
1.00
(0.00 - 3.00)
1.00
(0.00 - 3.00)
0.100 s
(0.000 - 5.000 s)
Determined by A1-02
(10 - 300 Hz)
1.0 degrees
(0.1 - 5.0 degrees)
0.3Hz
(0.1 - 20.0 Hz)
10.0 Hz
(1.0 - 30.0 Hz)
15.0 degrees
(0.0 - 30.0 degrees)
200.0 Hz
(100.0 - 1000.0 Hz)
10.0%
(0.0 - 100.0%)
0.0%
(-10.0 - +10.0%)
0
(0, 1)
0
(0, 1)
SIEPCYEUOQ2V01A Q2V Technical Manual
Ref.
484
484
484
485
485
485
485
485
486
486
486
486
486
486
486