4.10 Test Run

4.10

Test Run

After you set the basic parameters and do Auto-Tuning, do a test run.
WARNING! Crush Hazard. Test the system to make sure that the drive operates safely after you wire the drive and set
parameters. If you do not test the system, it can cause damage to equipment or serious injury or death.

No-Load Test Run

Before connecting the motor to the machine, make sure that you check the operation status of the motor.
Precautions before Operation
Before rotating the motor, check these items:
• Check for safety issues near the drive, motor, and machine.
• Make sure that all emergency stop circuits and machine safety mechanisms are operating correctly.
Items to Check before Operation
Check these items before operation:
• Is the motor rotating in the forward direction?
• Is the motor rotating smoothly (no unusual sounds or unusual vibrations)?
• Does the motor accelerate/decelerate smoothly?

Do a No-Load Test Run

Do these steps for a no-load test run:
1.
Energize the drive, or push
2.
Push
to illuminate the LOCAL/REMOTE LED.
3.
Use
/
4.
Push
.
The RUN indicator illuminates, and the motor runs at 6.00 Hz in the forward direction.
5.
Make sure that the motor is rotating in the correct direction and that the drive does not show a fault.
If the drive detects a fault, remove the cause.
A - Forward Rotation of Motor (Counter Clockwise Direction as Seen from
6.
Push
to increase the frequency reference value.
Change the setting value in increments of 10 Hz if necessary and examine the response.
Ex.: 6 Hz → 20 Hz → 30 Hz → 40 Hz → 50 Hz → 60 Hz
7.
Each time you increase the setting value, use U1-03 [Output Current] to check the drive output current.
When the output current of the drive is not more than the motor rated current, the status is correct.
8.
Make sure that the motor rotates correctly, then push
The RUN LED flashes and goes off when the motor stops completely.

Actual-Load Test Run

Test the operation without a load, then connect the motor and machine to do a test run.
Precautions before Operation
Before rotating the motor, check these items:
• Check for safety issues near the drive, motor, and machine.
• Make sure that all emergency stop circuits and machine safety mechanisms are operating correctly.
130
to show the frequency reference screen.
/
/
to set d1-01 = 6.00 [Reference 1 = 6.00 Hz], then push
Load Shaft)
.
SIEPCYEUOQ2V01A Q2V Technical Manual
.