Omron Q2V Series Technical Manual page 382

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

11.12 o: KEYPAD
No.
Name
(Hex.)
1stMon Area Selection
o1-41
(11C1)
RUN
1stMon Area Setting
o1-42
(11C2)
RUN
2ndMon Area Selection
o1-43
(11C3)
RUN
2ndMon Area Setting
o1-44
(11C4)
RUN
3rdMon Area Selection
o1-45
(11C5)
RUN
3rdMon Area Setting
o1-46
(11C6)
RUN
Trend Plot 1 Min Scale
o1-47
Value
(11C7)
RUN
Trend Plot 1 Max Scale
o1-48
Value
(11C8)
RUN
Trend Plot 2 Min Scale
o1-49
Value
(11C9)
RUN
Trend Plot 2 Max Scale
o1-50
Value
(11CA)
RUN
Trend Plot Time Scale
o1-51
Setting
(11CB)
RUN
AnGauge Area Selection
o1-55
(11EE)
RUN
AnGauge Area Setting
o1-56
(11EF)
RUN
Mot Capacity Unit
o1-58
(3125)
382
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the horizontal range used to display the monitor set in o1-24 [Cust.Monitor 1] as a
bar graph. This parameter is only available when using an LCD keypad.
0 : +/- Area (- o1-42 - o1-42 )
1 : + Area (0 - o1-42 )
2 : - Area (- o1-42 - 0)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the horizontal axis value used to display the monitor set in o1-24 [Cust.Monitor 1]
as a bar graph. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Selects the horizontal range used to display the monitor set in o1-25 [Custom Monitor
2] as a bar graph. This parameter is only available when using an LCD keypad.
0 : + - Area (- o1-44 - o1-44)
1 : + Area (0 - o1-44)
2 : - Area (- o1-44 - 0 )
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the horizontal axis value used to display the monitor set in o1-25 [Cust.Monitor 2]
as a bar graph. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the horizontal range used to display the monitor set in o1-26 [Cust.Monitor 3] as a
bar graph. This parameter is only available when using an LCD keypad.
0 : + - Area (- o1-46 - o1-46)
1 : + Area (0 - o1-46 )
2 : - Area (- o1-46 - 0 )
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the horizontal axis value used to display the monitor set in o1-26 [Cust.Monitor 3]
as a bar graph. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the horizontal axis minimum value used to display the monitor set in o1-24 [Cust.
Monitor 1] as a trend plot. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the horizontal axis maximum value used to display the monitor set in o1-24 [Cust.
Monitor 1] as a trend plot. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the horizontal axis minimum value used to display the monitor set in o1-25 [Cust.
Monitor 2] as a trend plot. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the horizontal axis maximum value used to display the monitor set in o1-25 [Cust.
Monitor 2] as a trend plot. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the time scale (horizontal axis) to display the trend plot. When you change this
setting, the drive automatically adjusts the data sampling time. This parameter is only
available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the range used to display the monitor set in o1-24 [Custom Monitor 1] as an analog
gauge. This parameter is only available when using an LCD keypad.
0 : + - Area (- o1-56 - o1-56 )
1 : + Area (0 - o1-56 )
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the value used to display the monitor set in o1-24 [Cust.Monitor 1] as an analog
meter. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the setting unit for parameters that set the motor rated power.
0 : kW
1 : HP
Default
(Range)
0
(0 - 2)
100.0%
(0.0 - 100.0%)
0
(0 - 2)
100.0%
(0.0 - 100.0%)
0
(0 - 2)
100.0%
(0.0 - 100.0%)
-100.0%
(-300.0 - +300.0%)
100.0%
(-300.0 - +300.0%)
-100.0%
(-300.0 - +300.0%)
100.0%
(-300.0 - +300.0%)
300 s
(1 - 3600 s)
1
(0, 1)
100.0%
(0.0 - 100.0%)
0
(0, 1)
SIEPCYEUOQ2V01A Q2V Technical Manual
Ref.
699
699
699
699
699
700
700
700
700
700
700
700
700
701

Advertisement

Table of Contents
loading

Table of Contents