Omron Q2V Series Technical Manual page 513

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

d1-13: Reference 13
No.
Name
(Hex.)
d1-13
Reference 13
(028E)
RUN
Note:
• The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
• When A1-02 = 6 [Control Method = PM AOLVector], the drive sets o1-03 = 1 [0.01% (100%=E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 13.
d1-14: Reference 14
No.
Name
(Hex.)
d1-14
Reference 14
(028F)
RUN
Note:
• The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
• When A1-02 = 6 [Control Method = PM AOLVector], the drive sets o1-03 = 1 [0.01% (100%=E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 14.
d1-15: Reference 15
No.
Name
(Hex.)
d1-15
Reference 15
(0290)
RUN
Note:
• The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
• When A1-02 = 6 [Control Method = PM AOLVector], the drive sets o1-03 = 1 [0.01% (100%=E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 15.
d1-16: Reference 16
No.
Name
(Hex.)
d1-16
Reference 16
(0291)
RUN
Note:
• The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
• When A1-02 = 6 [Control Method = PM AOLVector], the drive sets o1-03 = 1 [0.01% (100%=E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 16.
d1-17: Jog Reference
No.
Name
(Hex.)
d1-17
Jog Reference
(0292)
RUN
Note:
• The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
• When A1-02 = 6 [Control Method = PM AOLVector], the drive sets o1-03 = 1 [0.01% (100%=E1-04)].
SIEPCYEUOQ2V01A Q2V Technical Manual
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the Jog frequency reference in the units from o1-03 [FrqDisplay Unit Selection]. Set H1-xx
= 6 [MFDI Function Select = Jog Reference] to use the Jog frequency reference.
Description
Description
Description
Description
Description
12.4 d: REFERENCE
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
6.00 Hz
(0.00 - 590.00 Hz)
513
12

Advertisement

Table of Contents
loading

Table of Contents