DISPlay Subsystem

Trace Y-Axis Scaling

:DISPlay:WINDow:TRACe:Y[:SCALe]:PDIVision <rel_ampl>
:DISPlay:WINDow:TRACe:Y[:SCALe]:PDIVision?
Sets the per-division display scaling for the y-axis.
Factory Preset
and *RST:
10 dB
Range:
0.01 to 20.0 dB
Default Unit:
dB
Front Panel
Access:
AMPLITUDE/Y Scale, Scale/Div

Trace Y-Axis Reference Level

:DISPlay:WINDow:TRACe:Y[:SCALe]:RLEVel <ampl>
:DISPlay:WINDow:TRACe:Y[:SCALe]:RLEVel?
Sets the amplitude value of the reference level for the y-axis.
Factory Preset
and *RST:
0 dBm
−149.9 to 50 dBm with zero reference level offset
Range:
Default Unit:
current active units
Remarks:
The input attenuator setting may be affected. The
minimum displayed value of reference level is –327.6,
and the maximum displayed value is 327.6.
Front Panel
Access:
Amplitude Y Scale, Ref Level

Trace Y-Axis Reference Level Offset

:DISPlay:WINDow:TRACe:Y[:SCALe]:RLEVel:OFFSet <rel_ampl>
:DISPlay:WINDow:TRACe:Y[:SCALe]:RLEVel:OFFSet?
Sets the amplitude level offset for the y-axis.
Factory Preset
and *RST:
0 dB
Range:
–327.6 to 327.6 dB
Default Unit:
dB