AVENSIS REPAIR MANUAL (RM1018E)
ENGINE CONTROL SYSTEM
7.
INSPECT CIRCUIT OPENING RELAY
(a)
Inspect the relay continuity.
(1)
Specified condition: Continuity
(2)
Specified condition: No continuity
(b)
Inspect the relay operation.
E34090
(1)
(2)
Specified condition: Continuity
http://vnx.su
–
SFI SYSTEM (1AZ–FSE)
Using an ohmmeter, check that there is continuity
between terminals 1 and 2.
Check that there is no continuity between terminals
3 and 5.
Apply battery voltage across terminals 1 and 2.
Using an ohmmeter, check that there is continuity
between terminals 3 and 5.
10–41