Cooling fan
Standard amperage
Standard amperage (No.2 (With Air Conditioner))
Cooling fan relay
Specified condition
Cooling fan relay No.2
Specified condition
Cooling fan relay No.3
Specified condition
1CD–FTV:
Thermostat
Valve opening temperature
Valve lift
Radiator cap sub–assy
Standard opening pressure
Minimum opening pressure
Cooling fan
Standard amperage
Cooling fan relay
Specified condition
Cooling fan relay No.2
Specified condition
Cooling fan relay No.3
Specified condition
AVENSIS REPAIR MANUAL (RM1018E)
SERVICE SPECIFICATIONS
–
at 20YC (68YF)
at 20YC (68YF)
Between terminals 1 and 2
Between terminals 3 and 5
Between terminals 1 and 2
Between terminals 3 and 4
Between terminals 3 and 5
Between terminals 1 and 2
Between terminals 3 and 5
at 95YC (203YF)
at 20YC (68YF) 13.2 A
Between terminals 1 and 2
Between terminals 3 and 5
Between terminals 1 and 2
Between terminals 3 and 4
Between terminals 3 and 5
Between terminals 1 and 2
Between terminals 3 and 5
http://vnx.su
COOLING
5.2 to 8.2 A (M/T) 8.3 to 11.3 (A/T)
5.2 to 8.2 A (M/T) 8.3 to 11.3 (A/T)
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
Continuity
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
80 – 84YC (176 – 183YF)
8.5 mm (0.33 in.) or more
93 – 122 kPa (0.95 – 1.25 kgf/cm2, 13.4 – 17.6 psi)
78 kPa (0.8 kgf/cm2, 11.4 psi)
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
Continuity
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
Continuity
No continuity
Continuity (Apply battery voltage terminals 1 and 2)
03–25