Chapter 10 DSL Port Setup Screens
DESCRIPTION
Select the number of a DSL port on the line card.
Click Load to display the port's PVC settings in the PVC Table.
This is the number of the PVC on this port. Click a number to open a screen where
you can add the channel to more VLANs (or remove it from VLANs).
This field displays the Virtual Path Identifier (VPI) and Virtual Circuit Identifier
(VCI). The VPI and VCI identify a channel on this port.
This field displays the ATM profile that this channel uses.
This field displays the encapsulation type (llc or vc) for this channel.
This field displays whether the channel is a PVC or a PPVC.
This field displays the PVID (Port VLAN ID) to assign to untagged frames received
on this channel.
This field displays the priority value (0 to 7) that the line card adds to frames that
come in on this PVC without a (IEEE 802.1p) priority tag.
Select a PVC's radio button and then use the Modify, Copy or Delete button.
Click Modify to display the selected PVC's settings in the fields above so you can
edit them.
Do the following to copy VLAN and PVC settings from one DSL port to another
DSL port or ports.
1. Use the Select column to choose a PVC which you want to copy to another
port.
2. Click Copy to open the following screen.

Figure 94 Copy

3. Select a line card to which you want to copy settings.
4. Select the check boxes of the DSL ports on the line card to which you want to
copy the settings. Click Select All to mark all of the port check boxes or click
Select None to clear all of the port check boxes.
5. Click Apply to copy the settings to all of the ports that you have selected in this
screen. Click Cancel to close the screen without saving changes.
Click Delete to remove the selected PVC.
Type the Virtual Path Identifier and Virtual Circuit Identifier for a PPVC on this port.
Type a PVID (Port VLAN ID) to assign to untagged frames received on this PPVC.
This must be the VLAN ID of a VLAN that is already configured. The port that you
are configuring must also be set to the fixed status in the VLAN.
Use the drop-down list box to select an ATM profile to assign to this PPVC.
Select the encapsulation type (llc or vc) for this PPVC.