MSC1000G User's Guide
The following example sets the speed of the uplink 1 Gigabit Ethernet interface to 1000 Mbps
and the duplex to full.
ras>
switch port speed up1 1000F
28.10 switch port vlantrunk Commands
Use these commands to turn VLAN trunking on or off for the Gigabit Ethernet interfaces.
28.10.1 switch port vlantrunk enable Command
Syntax:
switch port vlantrunk enable <giga-port>
where
<giga-port>
This command sets a Gigabit Ethernet interface(s) to use VLAN trunking in order to accept
frames with any VID.
The following example sets the subtending 1Gigabit Ethernet interface to use VLAN trunking.
ras>
switch port vlantrunk enable sub1
28.10.2 switch port vlantrunk disable Command
Syntax:
switch port vlantrunk disable <giga-port>
where
<giga-port>
This command sets a Gigabit Ethernet interface(s) to not use VLAN trunking so the port only
accepts frames with registered VIDs.
The following example sets the subtending 1Gigabit Ethernet interface to not use VLAN
trunking.
482
=
This represents Gigabit Ethernet uplink ports, subtending ports
or all ports. Use
sub1|sub2|up1|up2|all i
enabled. Use
tsub|tup|all
=
This represents Gigabit Ethernet uplink ports, subtending ports
or all ports. Use
sub1|sub2|up1|up2|all i
enabled. Use
tsub|tup|all
f trunking is not
if trunking is enabled.
f trunking is not
if trunking is enabled.