Ip Set Command; Configuring Management Vlan Example - ZyXEL Communications MSC1000G User Manual

Ies-5000 series management switch card
Hide thumbs Also See for MSC1000G:
Table of Contents

Advertisement

Use the command to display the current management IP settings. An example is shown next.
ras> ip show
interface
--------- --------------- --------------- ----
inband
outband
gateway: 172.23.15.254

22.2.9 ip set Command

Syntax:
ras> ip set inband|outband <ip>[/<netmask>] [<inband-vid>]
where
inband
outband
[<inband-
vid>]
This command sets the system's IP addresses and in-band management VLAN (CPU). You
can only manage the MSC through ports that are members of the management VLAN.
Note: By default, you can access the management VLAN from all of the IES-5000's
in-band ports since they are all in the management VLAN. If you need more
security, please see the following example.

22.2.9.1 Configuring Management VLAN Example

Note: After the following example configuration, you must connect through the third
Ethernet port (uplink port 1) in order to perform inband management. You must
connect through a VLAN aware device that is using the proper VLAN ID in
order to perform management.
Another option would be to set the PVID of the third Ethernet port to 3, but this
is not recommended since all Ethernet frames received on the port without a
VLAN tag would be considered part of VLAN 3.
By default, the DSL ports are members of the management VLAN (VID 1). The following
procedure shows you how to configure a tagged VLAN that limits management access to just
one Ethernet port.
Note: Use the out-of-band management port or console port to configure the MSC if
you misconfigure the management VLAN and lock yourself out from performing
in-band management.
Chapter 22 ip Commands
interface ip
netmask
192.168.1.2
255.255.255.0
172.23.15.86
255.255.255.0
=
Sets the in-band management IP address.
=
Sets the out-of-band management IP address (for the MGMT port).
=
Sets the VLAN ID (Identifier) of the management (CPU) VLAN. You
must connect to the MSC through a port that is a member of the
management (CPU) VLAN in order to perform in-band management.
MSC1000G User's Guide
vid
1
-
337

Advertisement

Table of Contents
loading

Table of Contents