Figure 105 Alarm Adsl Profile; Table 66 Alarm Adsl Profile - ZyXEL Communications MSC1000G User Manual

Ies-5000 series management switch card
Hide thumbs Also See for MSC1000G:
Table of Contents

Advertisement

Figure 105 Alarm ADSL Profile

The following table describes the fields in this screen.

Table 66 Alarm ADSL Profile

LABEL
The top part of the screen is for profile configuration.
Name
Threshold
ATU-C
ATU-R
15 Min LOF
[0~900]
15 Min LOS
[0~900]
15 Min LOL
[0~900]
15 Min LPR
[0~900]
15 Min ES
[0~900]
15 Min SESL
[0~900]
Chapter 11 Profile Screens
DESCRIPTION
Type a name to identify the alarm profile (you cannot change the name of the
DEFVAL profile). You can use up to 31 ASCII characters; spaces are not allowed.
Specify limits for the individual performance counters. The system sends an alarm
trap and generates a syslog entry when one of these thresholds is exceeded. A
value of 0 disables the alarm threshold.
These fields are for traffic coming from the subscriber's device to the system.
These fields are for traffic going from the system to the subscriber's device.
This field sets the limit for the number of Loss Of Frame seconds that are permitted
to occur within 15 minutes.
This field sets the limit for the number of Loss Of Signal seconds that are
permitted to occur within 15 minutes.
This field sets limit for the number of Loss Of Link seconds that are permitted to
occur within 15 minutes.
This field sets the limit for the number of Loss of Power (on the ATUR) seconds
that are permitted to occur within 15 minutes.
This field sets the limit for the number of Errored Seconds that are permitted to
occur within 15 minutes.
This field sets the limit for the number of Severely Errored Seconds that are
permitted to occur within 15 minutes.
MSC1000G User's Guide
175