Configuring SNMP & RMON
Figure 6-10 Event Configuration
4) Choose SNMP > RMON > Alarm to load the following page. Configure entries 1 and 2.
For entry 1, set the alarm variable as BPackets, related statistics entry ID as 1 (bound
to port 1/0/1), the sample type as Absolute, the rising threshold as 3000, associated
rising event entry ID as 1 (which is the notify type), the falling threshold as 2000, the
associated falling event entry ID as 2 (which is the log type), the alarm type as all, the
interval as 10 seconds, the owner name as monitor. For entry 2, set the associated
statistics entry ID as 2 (bound to port 1/0/2). Other configurations are the same as
those of entry 1.
Figure 6-11 Alarm Configuration
5) Click Save Config to save settings.
6.5 Using the CLI
Configuring Rate Limit on ports
Configure the rate limit on required ports. For detailed configuration, please refer to
Configuring
QoS.
Configuration Example
Configuration Guide