Chapter 2
Avaya P330-ML Layer 2 CLI Commands
Example:
P330-N# set ppp incoming timeout 15
PPP incoming session will automatically disconnect after 15
minutes of idle time

set psu type

User level: privileged, supervisor.
Use the set psu type command to set the main power supply type (AC/DC) of
the module.
This command is not applicable to P330-ML-ML switches, which determine the
PSU type automatically. This command is used to set the power supply types
for other P330-ML switches in the stack.
The syntax for this command is:
set psu type [AC|DC][module number]
Example:
P330-N# set psu type DC 3
Power supply type was changed to DC on module 3

set qos policy-source

User level: supervisor
This command applies to the P334T-ML only when it is in device mode
"Layer2".
Use the set qos policy-source command to set the policy source (local or
policy server).
The syntax for this command is:
set policy source <source>
source
Example:
P330-N# set qos policy-source local
Done!
108
local or policy server
• The default policy source for the P334T-ML switch is local