APPENDICES
(1) Diagnostic Information
Number
Name
OFF : No error
SM0
Diagnostic errors
ON : Error
OFF : No self-diagnosis
SM1
Self-diagnosis error
ON : Self-diagnosis
OFF : No error common
Error common
SM5
information
ON : Error common
OFF : No error individual
Error individual
SM16
information
ON : Error individual
SM50
Error reset
OFF
OFF : Normal
SM51
Battery low latch
ON : Battery low
OFF : Normal
SM52
Battery low
ON : Battery low
OFF : AC/DC DOWN not
AC/DC DOWN
SM53
detection
ON : AC/DC DOWN
OFF : Normal
SM54
MINI link errors
ON : Error
TableApp.2 Special relay
Meaning
• Turns ON if an error occurs as a result of diagnosis.
(Includes when an annunciator is ON, and when an
error is detected with CHK instruction)
• Remains ON if the condition is restored to normal
thereafter.
• Turns ON if an error occurs as a result of diagnosis.
(Includes when an annunciator is ON)
• Remains ON if the condition is restored to normal
thereafter.
• Turns ON if an error occurs as a result of diagnosis.
(Does not include when an annunciator is ON or
when an error is detected by the CHK instruction)
• Remains ON if the condition is restored to normal
thereafter.
errors
• Turns ON if an error occurs as a result of diagnosis.
(Does not include when an annunciator is ON)
• Remains ON if the condition is restored to normal
thereafter.
information
• When SM0 is ON, ON if there is error common
information
information
information
• When SM0 is ON, ON if there is error individual
information
information
• Conducts error reset operation
ON: Error reset
• ON if battery voltage at CPU module or memory card
drops below rated value.
• Remains ON if the battery voltage returns to normal
thereafter.
• Synchronizes with the BAT. ALARM/BAT.
LED.
• ON if battery voltage at CPU module or memory card
drops below rated value.
• Remains ON if the battery voltage returns to normal
thereafter.
• Synchronizes with the BAT. ALARM/BAT. LED.
• ON if battery voltage at CPU module or memory card
drops below rated value.
• Remains ON if the battery voltage returns to normal
thereafter.
• Synchronous with BAT. LED
• Same as SM51, but goes OFF subsequently when
battery voltage returns to normal.
• Turns ON if an instantaneous power failure of within
20ms occurs during use of the AC power supply
module.
Reset when power is switched OFF, then ON.
• Turns ON if an instantaneous power failure of within
detected
10ms occurs during use of the DC power supply
module.
detected
Reset when power is switched OFF, then ON.
• Turns ON if an instantaneous power failure of within
1ms occurs during use of the DC power supply
module.
Reset when power is switched OFF, then ON.
• Goes ON if MINI (S3) link error is detected at even
one of the installed AJ71PT32 (S3) modules.
• Remains ON if the condition is restored to normal
thereafter.
Set by
Explanation
(When Set)
S (Error)
S (Error)
S (Error)
S (Error)
S (Error)
S (Error)
S (Error)
S (Error)
S (Error)
S (Error)
S (Error)
S (Error)
Appendix 1 Special Relay List
Corres-
ponding
Corresponding CPU
ACPU
M9
QnA
Qn(H)
New
QnPH
QnPRH
Rem
New
Q00J/Q00/Q01
QnA
Qn(H)
M9008
QnPH
QnPRH
Rem
New
Q00J/Q00/Q01
New
Rem
New
U
New
QnA
M9007
Qn(H)
QnPRH
M9007
QnPH
New
Q00J/Q00/Q01
M9006
M9005
QCPU
QnA
M9004
App
9
10
11
- 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents