TableApp.28 Special register
Name
Meaning
Transition condition
Error transition
number where error
occurred
Sequence step
Error sequence
number where error
step
occurred
Status latch
Status latch step
Software
Software version of
version
internal software
PLC
Computer link data
communications
check
check
Number of
Number of empty
empty blocks in
blocks in
communications
communications
request
request registration
registrtion area
area
Register for
setting time
1 s to 65535 s
check value
Number of
Number of special
special
functions modules
functions
over
modules over
Detailed error
Self-diagnosis
code
detailed error code
Head I/O
Head I/O number of I/
number of I/O
O module to be
module to be
replaced
replaced
DIP switch
DIP switch
information
information
Details
• Stores the transition condition number, where error code 84 occurred
in an SFC program, in BIN value.
Stores "0" when error code 80, 81, 82 or 83 occurred.
• Stores the sequence step number of transfer condition and
operation output in which error 84 occurred in the SFC program in
BIN code.
• Stores the step number when status latch is executed.
• Stores the step number in a binary value if status latch is executed
in a main sequence program.
• Stores the block number and the step number if status latch is
executed in a SFC program.
Block No.
Step No.
(BIN)
Lower 8 bits
Upper 8 bits
• Stores the software version of the internal system in ASCII code.
Stored into lower
Higher byte Lower byte
byte
Undefind value in
higher byte
For version "A", for example, "41
Note: The software version of the initial system may differ from the
version indicated by the version information printed on the rear
of the case.
• In the self-loopback test of the serial communication module, the
serial communication module writes/reads data automatically to
make communication checks.
• Stores the number of empty blocks in the communication request
registration area to the remote terminal module connected to the
MELSECNET/MINI-S3 master unit, A2CCPU or A52GCPU.
• Sets the time check time of the data link instructions (ZNRD,
ZNWR) for the MELSECNET/10.
• Setting range : 1 s to 65535 s (1 to 65535)
• Setting unit
: 1 s
• Default value : 10 s (If 0 has been set, default 10 s is applied)
• For details, refer to the manual of each microcomputer program
package.
• Stores the detail code of cause of an instruction error.
• Stores the first two digits of the head I/O number of the I/O module,
which will be dismounted/mounted online (with power on), in BIN
value.
Example) Input module X2F0
H2F
• The DIP switch information of the CPU module is stored in the
following format.
0: OFF
1: ON
to
b15
b5
b4
b3
b2
D9095
0
Appendix 2 Special Register List
Corresponding CPU
QnA
Qn(H)
QnPH
(BIN)
QnA
" is stored.
H
QnA
Qn(H)
QnPH
QnA
QnA
Qn(H)
QnPH
b1
b0
Qn(H)
QnPH
SW1
SW2
SW3
SW4
SW5
App
9
10
11
- 64