NT8D15 E and M Trunk card
Table 189: Power requirements
+15.0 V dc
–15.0 V dc
+8.5 V dc
–48.0 V dc

Environmental specifications

Table 190: Environmental specifications
specifications for the E and M Trunk card.
Table 190: Environmental specifications
Operating temperature
Operating humidity
Storage temperature

Foreign and surge voltage protection

The E and M Trunk card meets CS03 over-voltage (power cross) specifications and FCC Part
68 requirements.

Connector pin assignments

The E and M Trunk card brings the four analog trunks to the backplane through a 160-pin
connector shroud. The backplane is cabled to the I/O panel on the rear of the module, which
is then connected to the Main Distribution Frame (MDF) by 25-pair cables.
Telephone trunks connect to the E and M Trunk card at the MDF using a wiring plan similar to
that used for line cards.
A typical connection example is shown in
connection example
various 2-wire modes is shown in
452
Circuit Card Reference
Voltage
±5%
±5%
±2%
±5 %
Parameter
on page 454. A list of the connections to the E and M Trunk card in the
Comments? infodev@avaya.com
Tolerance
on page 452 provides the environmental
0 to +60 degrees C (32 to +140 degrees F),
ambient
5 to 95% RH (non-condensing)
–40 to +70 degrees C (–40 to +158 degrees
F)
Figure 144: E and M Trunk card - typical cross
Table 191: E and M Trunk card - backplane pinouts for 2-
Max current
200 mA
200 mA
200 mA
415 mA