NT6D80 MSDL card
Symptom:
Diagnosis:
Action:
OR
Diagnosis:
Action:
Symptom:
Diagnosis:
Action:
OR
Diagnosis:
Action:

System disabled actions

These explain the causes of problems and the actions needed to return the card to an enabled
state following system disabling.
SYSTEM DISABLED—NOT RESPONDING:
Table 150:
Cause:
The MSDL card is not installed or is unable to respond to the messages from the
system.
Action:
Check the MSDL messages on the console and take the action recommended.
Refer to Software Input/Output Reference — Administration (NN43001-611).
Verify that the address switches on the MSDL are set correctly.
Verify that the card is properly installed in the shelf for at least 5 minutes.
342
Circuit Card Reference
The LED on the MSDL card is steadily lit.
The MSDL card is disabled or faulty.
Refer to
Trunk cards
on page 57.
Peripheral software download failed because of MSDL card
or system disk failure.
If only one MSDL card has its LED lit, replace it.
Autorecovery is activated every 30 seconds to enable the
MSDL. MSDL300 messages appear on the console or TTY.
The MSDL card is system disabled because of an incorrect
address.
Verify the switch settings.
The MSDL card is system disabled because of peripheral
software or configuration errors.
Refer to