Power consumption
The SDI cards obtain their power directly from the module backplane. Power consumption for
each of the cards is shown in
Table 10: Power consumption
+5 VDC ±5%
+12 VDC ±5%
–12 VDC ±5%
Environmental
The SDI cards operate without degradation under the conditions listed in
Environmental specifications
Table 11: Environmental specifications
Specification
Ambient temperature
Relative humidity (non-
condensing)
Electrostatic discharge
The SDI cards meet the requirements of the IEC 801-2, clause 8.0 procedure. They can
withstand a direct discharge of ±5 to ±20 kV without being damaged.
68
Circuit Card Reference
Table 10: Power consumption
Voltage
on page 68.
0° to 50°C; (32° to 122°F)
Altitude
Comments? infodev@avaya.com
Maximum power consumption
NT8D41BA
1.0 Amp
100 mA
100 mA
Operation
5% to 95%
3500m; (11 000 ft)
on page 68.
QPC841
1.5 Amp
100 mA
100 mA
Table 11:
Storage
–55° to +70°C; (–58° to
158°F)
0% to 95%
15 000m; (50 000 ft)