Avaya Nortel Communication Server 1000 Reference page 80

Circuit card reference
Hide thumbs Also See for Nortel Communication Server 1000:
Table of Contents

Advertisement

Acceptance tests
2. Request the status of a loop on the conference card:
3. If the conference card loop is disabled, enable it.
4. Test the conference loop for channel, group, and switching faults: CNFC loop
5. Prepare the system for a manual conference call on a specified loop: CNFC MAN
80
Circuit Card Reference
LOGI (password)
LD 38 STAT loop
Conference status is formatted as follows:
CNFC n DSBL n BUSY "n" represents the number of conference groups disabled
and busy
CHAN n DSBL n BUSY "n" represents the number of channels disabled and busy
UNEQ card is not equipped in the system
DSBL card is disabled in software
For an NT8D17 Conference/TDS card, enter: ENLX loop (the conference loop is
the odd loop of the conference/TDS loop pair)
Note:
The conference/TDS card is not enabled automatically when it is inserted. You
must enable the card with the command ENLX. (This command is used in LD 34
and LD 46 to address even loops and in LD 38 to address odd loops.) Enabling
the loops with the command ENLL does not enable the hardware for the card.
For other than an NT8D17 Conference/TDS card, enter: ENLL loop (the
conference loop must be an even loop for cards other than the NT8D17)
If the system response is other than OK, see Software Input/Output Reference —
Administration (NN43001-611) to analyze the messages.
If the conference loop passes the tests, the output is OK .
If the system response is other than OK , see Software Input/Output Reference —
Administration (NN43001-611) to analyze the messages.
loop c Where "c" is the manual conference group (1-15)
A manual conference test is performed by stepping through conference channels
and groups and listening for noise that indicates a faulty card.
The manual conference test can be performed through a system terminal or BCS
maintenance telephone. If commands are entered from a maintenance telephone,
this telephone automatically becomes part of the manual conference call.
Only one manual conference call is allowed at one time. A manual conference
consists of only two telephones, where one telephone acts as a signal source while
the other acts as a listening monitor.
After you enter the CNFC command, any two telephones (one may already be the
maintenance telephone) dialing the special service prefix code (SPRE) and the
Comments? infodev@avaya.com