Avaya Nortel Communication Server 1000 Reference page 579

Circuit card reference
Hide thumbs Also See for Nortel Communication Server 1000:
Table of Contents

Advertisement

Prompt
TKTP
ICOG
CNTL
TIMER
MR
Trunk Data Block
Respond to the prompts in LD 14.
Table 249: LD 14 - Trunk Data Block for NTCK16BX
Prompt
REQ:
TYPE:
TN
6
XTRK
CDEN
SIGL
BTID (See
Pulse Metering
page 580.)
SUPN
STYP
CLS
6
These prompts are required only for the first unit defined on each NTCK16BX card.
Circuit Card Reference
Response
0-127
COT
IAO
YES
RGV 256
(NO)
Response
NEW
COT
l s c u
XCOT
(8D)
LOP
Periodic
Xx
on
(NO) YES
BTS
BAT
(LOL) SHL
Description
Range for Small System, CS 1000E system,
Media Gateway 1000B, and Media Gateway
1000T
Define trunk type as Central Office
Incoming and Outgoing trunk
Change a trunk timer
Set Ring Validation Timer to 128 ms.
PPM is off on this route.
Description
Define a new trunk unit.
Central Office Trunk
Terminal Number
Format for Large System, Call Server 1000E,
and Media Gateway 1000E, where l = loop,
s = shelf, c = card, u = unit
Type is IPE COT
Card density is 8D (default).
Loop start signaling
Enter the country busy tone ID:
Tortola, Brazil = 10 Mexico = 10 or 08
(depending on CO) Singapore = 11 Ireland =
3 or 9 (depending on CO) Kuwait, Chile,
Venezuela, Indonesia, Thailand,Korea = 06
Argentina = 12 or 07Turkey = 14
Supervision yes (no)
Busy tone supervision enabled
Loop break supervision enabled
Attenuation Pads In, (Out)
Configuration
July 2011
579

Advertisement

Table of Contents
loading

Table of Contents