NT8D14 Universal Trunk card

Jumper strap settings

For most applications, the jumper strap settings remain set to the standard configuration as
shipped from the factory. See
NT8D14BB)
The jumper strap settings must be changed, as shown in
extended range (NT8D14BA, NT8D14BB, NT8D14BB)
• For CO/FX/WATS or TIE trunk loops exceeding 1524 meters (5000 ft.)
• DID trunks exceeding a loop resistance of 600 ohms
• RAN trunks operating in pulse start or level start modes
Figure 130: Universal trunk card - jumper locations for NT8D14BA and NT8D14BB Release 9
and below
Note:
Refer to Circuit Card Reference (NN43001-311) for vintage AA jumper strap settings.
424
Circuit Card Reference
Table 175: Jumper strap settings - factory standard (NT8D14BA,
on page 421.
on page 425 shows jumper locations on the universal trunk card (vintage BA).