Implementation Guidelines; Environmental And Power Requirements - Avaya Nortel Communication Server 1000 Reference

Circuit card reference
Hide thumbs Also See for Nortel Communication Server 1000:
Table of Contents

Advertisement

NT6D80 MSDL card
Pin
24
Terminal Timing (TTb)

Implementation guidelines

The following are guidelines for engineering and managing MSDL cards:
• An MSDL can be installed in any empty network card slot.
• A maximum of eight MSDL cards can be installed in a fully occupied module because of
the module's power supply limitations.
• The Clock Controller card should not be installed in a module if more than 10 MSDL ports
are configured as active RS-232 (rather than RS-422) ports in that module because of
the module's power supply limitations.
• The MSDL address must not overlap other card addresses.
• Before downloading a peripheral software module for an MSDL, disable all MSDL ports
on cards running the same type of operation.

Environmental and power requirements

The MSDL card conforms to the same requirements as other interface cards. The temperature,
humidity, and altitude for system equipment, including the MSDL, should not exceed the
specifications shown in
Table 146: Environmental requirements
Operating
Temperature
Relative Humidity
Altitude
Storage
Temperature
Relative Humidity
A stable ambient operating temperature of approximately 22°C (72°F) is recommended. The
temperature differential in the room should not exceed ±3°C (±5°F).
The internal power supply in each module provides DC power for the MSDL and other cards.
Power consumption and heat dissipation for the MSDL is listed in
consumption
328
Circuit Card Reference
Signal Name
Table 146: Environmental requirements
Condition
on page 329.
Comments? infodev@avaya.com
EIA Circuit
Environmental specifications
0° to 50° C (32° to 122° F)
5% to 95% non-condensing
3,048 meters (10,000 feet) maximum
–50° to 70° C (–58° to 158° F)
5% to 95% non-condensing
DTE
DCE
DAa
X
on page 328.
Table 147: MSDL power
July 2011

Advertisement

Table of Contents
loading