Environmental Specifications; Front View Of Server - Avaya S8510 Installation Manual

Server family and its components
Hide thumbs Also See for S8510:
Table of Contents

Advertisement

Environmental specifications

Operating
temperature
Storage temperature
Operating relative
humidity
Storage relative
humidity
Operating maximum
vibration
Storage maximum
vibration
Operating maximum
shock
Storage maximum
shock
Operating altitude
Storage altitude

Front view of server

1
Power-on LED
2
NMI button (unused)
Installing the Avaya S8510 Server Family and Its Components
10° to 35° C (50° to 95° F)
–40° to 65° C (–40° to 149° F)
8% to 85% (noncondensing) with a maximum humidity gradation
of 10% per hour
5% to 95% (noncondensing)
0.25 G at 3–200 Hz for 15 min
0.5 G at 3–200 Hz for 15 min
One shock pulse in the positive z axis (one pulse on each side of
the system) of 41 G for up to 2 ms
Six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the system) of
71 G for up to 2 ms
–16 to 3048 m (–50 to 10,000 ft)
–16 to 10,600 m (–50 to 35,000 ft)
Environmental specifications